Error type
Error mode
Detergent is not
None
dispensed.
Copyright© 1995-2010 SAMSUNG. All rights reserved.
Checking Method
1) Check whether detergent is inserted into the dispenser.
2) Check the connections for the Dispenser connector.
3) Check the resistance of the Dispenser.
(Remove the connector before measuring.)
•
Normal: Approx. 2.3 kΩ
4) Check the operation of the Dispenser Relay.
Check the operating voltage between the white wire of the CN101
connector and the white wire of the CN201 connector.
•
Normal: 120V (while operating)
Corrective actions
Check whether there is detergent in the Dispenser.
•
•
Reconnect the Dispenser connector.
•
Faulty: Replace the Dispenser.
•
Faulty: Replace the Main PBA assy
•
Remove Retainer.
Check voltage
•