Samsung DMT300 Series Service Manual page 41

Hide thumbs Also See for DMT300 Series:
Table of Contents

Advertisement

Error type
Error mode
Main-PBA DC
None
Voltage Error
Copyright© 1995-2010 SAMSUNG. All rights reserved.
Checking Method
1) Check the DC voltage of the Main PBA.
Measure the voltage between pin 6 (amber) of the main PBA CN302
connector and pin 7 (pink) of the CN302 connector.
Normal: 4.5V to 5.5V
Measure the voltage between pin 6 (amber) of the main PBA CN302
connector and pin 9 (white) of the CN302 connector.
Normal (Power Key On): 9.5V to 12.5V
Normal (Power Key Off): 5.5V to 7.0V
Corrective actions
Faulty: Replace the Main-PBA Assy.
Remove Retainer.
Check voltage (4.5V~5.5V)
Check voltage (9.5V~12.5V or 5.5V~7.0V)
4. Troubleshooting
4-12

Hide quick links:

Advertisement

Table of Contents
loading