Settings; Cleaning, Care And Maintenance; Troubleshooting - STIEBEL ELTRON SHO AC 600 7,5 Operation And Installation Manual

Sealed unvented floorstanding cylinder
Hide thumbs Also See for SHO AC 600 7,5:
Table of Contents

Advertisement

Available languages

Available languages

OPERATION

Settings

4.
Settings
The temperature can be freely adjusted.
• Cold
I Low temperature setting, 35 °C
II Recommended setting for energy saving,
low scaling, 60 °C
III Maximum temperature setting, 85 °C
Depending on the system, the actual temperatures may vary from
the set value.
In the delivered condition, temperature selection is limited. This
limitation can be cancelled by a qualified contractor (see chapter
"Installation / Settings").
4.2.1 Appliance type with dual circuit operation and quick
heat-up function
The contractor needs to install a remote control to start the quick
heat-up function. The rapid heat-up function stops and will not
restart when the selected temperature has been reached.
5.

Cleaning, care and maintenance

f Have the electrical safety of the appliance and the function
of the safety assembly regularly checked by a qualified
contractor.
f Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
20
| SHO AC
Signal anode with consumption indicator
Material losses
!
If the consumption indicator changes colour from white
to red, have the signal anode checked by a heating con-
tractor and if necessary replaced.
1
5
4
1 Signal anode with consumption indicator
2 white = anode OK
3 Red
= ask your heating contractor to check
4 Temperature selector
5 Thermometer
Scaling
Almost every type of water will deposit lime at high temperatures.
This settles inside the appliance and affects both the performance
and service life. The heating elements must therefore be descaled
from time to time. A qualified contractor who knows the local
water quality will tell you when the next service is due.
f Check the taps/valves regularly. You can remove limescale
deposits at the spouts using commercially available descaling
agents.
f Regularly activate the safety valve to prevent it from becom-
ing blocked, e.g. by limescale deposits.
6.

Troubleshooting

Problem
Cause
The water does not heat
There is no power.
up.
The flow rate is low.
The aerator in the valve
or the shower head is
scaled up or contami-
nated.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000-0000-000000):
2
3
Remedy
Check the fuses/MCBs in
your fuse box.
Clean and/or descale the
aerator or shower head.
Nr.:
000000 - 0000 - 000000
www.stiebel-eltron.com

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sho ac 600 6/12Sho ac 1000 12Sho ac 1000 9/18

Table of Contents