Faults; Troubleshooting Guide (Water Supply); Disposal; Accessories - Truma Combi D6 CP plus ready Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10

Faults

Faults – Heater
Descriptions of possible fault causes and a troubleshooting
guide can be found in the operating instructions for the con-
trol panel that is installed.
Faults – Water supply
Possible fault causes and a troubleshooting guide – See

"Troubleshooting guide (water supply)".

Troubleshooting guide (water supply)
Fault
Water taking an extremely
long time to heat up.
Water running out, cannot fill
boiler.
Cannot empty boiler, even
though safety/drain valve is
open.
Water dripping/flowing from
drainage socket of safety/
drain valve.
After the heater has
been switched off, the
FrostControl opens.
The FrostControl can no
longer be closed.
If these actions do not remedy the problem, please
contact the Truma Service.

Disposal

The unit must be disposed of in line with the administrative
regulations of the respective country in which it is used. Na-
tional regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
In other countries, the relevant regulations must be observed.
16
Cause / Remedy
Water container furred. /
Descale water system (see
maintenance).
Safety/drain valve open. /
Close safety/drain valve.
Safety/drain valve drainage
socket blocked. / Inspect
opening for contamination
(slush, ice, leaves, etc.) and
remove contamination if
necessary.
Water pressure too high. /
Check pump pressure
(max. 2.8 bar). If connected to
a central water supply (rural or
urban connection), a pressure
reducer must be used, which
will prevent pressures higher
than 2.8 bar from occurring in
the boiler.
At temperatures of less than
approx. 3 °C the FrostControl
opens automatically / switch
heater on / without heater op-
eration the FrostControl can-
not be closed again until the
temperature reaches approx.
7 °C / use heating element for
FrostControl.
Temperature at FrostControl
less than approx. 7 °C / switch
heater on / without heater op-
eration the FrostControl can-
not be closed again until the
temperature reaches approx.
7 °C.
Rotary switch is not set to
"Operation". / Turn rotary
switch of FrostControl to
"Operation", then press push
button until it engages.

Accessories

Truma CP plus
CP plus digital control panel (part no. 36020-01) for
Combi D6 (E) CP plus ready.
Fig. 8
Truma CP E classic incl. CP classic
Analogue control panels (part no. 36010-02) consisting of
CP E classic (power selector switch – figure 9) and CP classic
(control panel – figure 10) for Combi D6 E CP plus ready.
Combi E
230 V~
Fig. 9
Truma CP classic
Analogue control panel (part no. 36010-01 – Fig. 11) for
Combi D6 (E) CP plus ready.
Fig. 11
FrostControl heating element
Heating element (part no. 70070-01) ) with 1.5 m connector
cable and retaining bracket.
Fig. 12
Other accessories (without picture) for control panels
– Cable 3 m (part no. 36110-01)
– Cable 6 m (part no. 36110-02)
– Cable 9 m (part no. 36110-03)
Combi
°
60
°
40
60
°
Fig. 10
Combi
°
60
°
40
60
°