Installation Instructions; Regulations And Provisions; Installation Location; Equipment Installation - STIEBEL ELTRON PSH 30 Si Instructions For Use And Installation

Hide thumbs Also See for PSH 30 Si:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4

2. Installation instructions

Installation instructions
for the installer

Regulations and provisions

– General national regulations
– Regulations of the local water
authority
– Regulations of the local electricity
authority
– Rating plate

Installation location

– Install vertical as in Fig.
– In an area free of the risk of freezing
– Install in the vicinity of the water tap

Equipment installation

– Install the device
When installing the device, select securing
materials to suit the stability of the wall
Temperature adjustment Fig.
PSH 30 Si / PSH 50 Si
The temperature adjustment for the PSH 30
Si and PSH 50 Si may be altered by the user
directly at the temperature knob.
For PSH 80-150 Si see Fig.
.
Water connection Fig.
Unvented (pressurized) for the supply of
several draw-off points.
A safety valve must be fitted with on
the cold water inlet of the unit, by a
skilled installer.
Fig.
Typ
PSH
30 Si
A
mm
623
B
mm
C
mm
345
D
mm
160
E
1/2"
F
mm
100
G
mm
81
H
mm
338
J
mm
345
K
mm
Type
PSH
30 Si
Content
30
Weight, emty
kg
14
Power rating
W
2000
Voltage
V
230
Permissible operating
pressure
bar
6
Standby current
consumption at
65 °C/24h
kW/h
0,73
for the qualified installer
Legend for Fig.
1 PSH wall-mounted water heater
3 Safety valve, 6 bar
4 Pressure Limiting valve
(recommended for pressures
over 5 bar)
5 Back-flow prevention device
6 Through-flow isolating valve
(throttle)
7 Cold water pipe
8 Drainage tap
9 Connection for isolating element
made of red brass or plastic, for
cold and hot water
10 Hot water pipe
11 Draw-off fittings
– Permissible operating
overpressure 6 bar.
– Install only type-tested safety
valves or safety groups.
Specific national regulations
are to be respected.
– Arrange the dimensions of the
drain to suit the fully-opened
safety valve. The drain aperture of
the safety valve must remain open
to the atmosphere.
– Adjust through-flow volume
max. 18 l/min at the through-flow
isolating valve (Fig.
– During the heating-up process,
water will visibly drip from the
safety valve.
50 Si
80 Si
100 Si
120 Si
918
780
911
1046
368
570
748
168
230
230
1/2"
3/4"
3/4"
100
230
230
81
170
170
338
505
505
345
520
520
440
440
50 Si
80 Si
100 Si
120 Si
50
80
100
17
26
31
2000
2200
2200
2200
230
230
230
6
6
6
0,99
0,97
1,21
– If water continues to drip from the
may be installed directly on the
device. We recommend that red
brass or plastic transition fittings be
used as connection isolators for the
pipe connections.
Parts Fig.
1 Plastic top cap
2 Wall brackets
3 Sheet steel housing, white
4 Cold water connection nozzle (blue)
5 Hot water connection nozzle (red)
6 Plastic bottom cap
7 Electric housing with electrical
8 Temperature knob (only PSH 30-50 Si)
9 Lamp
-6).
Steel tank enamelled with heating flange with
copper tubular heating element and
protection anode.
For test mark: see rating plate
Protection mode IP 25
G
150 Si
1256
498
798
748
1048
230
230
3/4"
3/4"
230
230
170
170
505
505
520
520
440
440
150 Si
120
150
34
40
2200
230
230
6
6
1,3
1,46
safety valve after the heating
system has been switched off, the
water pressure is too high (>6 bar),
or the safety valve has been
contaminated with dirt or is
defective.
Note with regard to copper pipes:
No connections made of copper
(on PSH 30 - 100 Si, on top only)
paint finish
connection
3
9
1
2
4, 5
6
7
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psh 150 siPsh 80 siPsh 50 si

Table of Contents