Installation Instructions; For The Qualified Installer - STIEBEL ELTRON DEL 18 SLi Operating And Installation Instructions

Electronically controlled instantaneous water heater
Table of Contents

Advertisement

Available languages

Available languages

2. Installation instructions

2.1 Brief description
The electronically controlled DEL ... SLi
electronic LCD instantaneous water heater is
a pressurised unit suitable for heating cold wa-
ter to DIN 1988 or for further heating water
pre-heated up to 55 °C.
The maximum permissible inlet temperature
is 65 °C. At higher temperatures the unit may
be damaged.
With the special fitting "Central thermostat"
(see "7. Special fittings") the max. inlet tempe-
rature can be limited to 60 °C.
One or more taps can be supplied with the
unit.
The bare-wire heating system is enclosed with
pressurised copper cladding.
The heating system is suitable for low-lime
and lime-containing water (see "5.2 Areas of
use").
for the qualified installer
2.2 Important information
Air trapped in the cold water supply
can damage the bare wire heating sys-
tem inside the equipment, or trip the safety
system (see "1.4 Important informati-
on").The DEL...SLi electronic LCD is
equipped with an air detector which,
to a great extent, prevents damage to
the heating system:
If, during operation, air is drawn into the
DEL ... electronic LCD, the equipment
shuts down the power for a few seconds,
thereby protecting the heating system.
• Valves:
• Stiebel Eltron pressure valves for instan-
taneous water heaters, for installation on
finished walls (see "7. Special accesso-
ries")
• Installation may be carried out using com-
mercially available pressure valves.
• Thermostatic pressure valves (see note
"1.8 Recommended adjustment").
• All information in these operating and
installation instructions must be followed
carefully. They contain important details
regarding safety, operation, installation and
maintenance of the equipment.
2.3 Instructions and regula-
tions
• The installation (water and electrical
work) and commissioning, as well as the
maintenance of this equipment, must only
be carried out by a qualified contractor in
accordance with these instructions.
• Perfect function and safe operation can
only be guaranteed when using original
accessories and spare parts intended for
this equipment.
• Observe all locally applicable instructions
and regulations regarding water and elec-
trical connections, such as DIN VDE 0100,
DIN 1988, DIN 4109, DIN 44851 etc.
• Observe all local water and electricity
supply company regulations.
• Install the lower area of the equipment
flush with the wall (observe dimension
≥ 110 mm B ).
• The type plate (open the hinged flap on
the equipment cap).
• See also "5. Specification".
The specific electrical resistance of
the water may not be below the value
written on the rating plate.
If the water is coming from a water-net-
work the lowest value of the water resist-
ance must be considered, (see „5.2 area of
application").
The specific electrical resistance of the
water is generally known by the water pro-
vider.
• Install the equipment only in an enc-
losed, frost-free room. Store dismantled
equipment in frost-free conditions, since
there is always a little water left inside the
equipment.
• The protection level IP 25 (hose-proof)
is only guaranteed if a correctly installed
cable grommet is used.
Water installation:
– Cold water pipe material:
Steel, copper or plastic pipe systems.
– DHW pipe material:
Copper or plastic pipe systems*
Operating temperatures up to a max.
60 °C can be reached with the
DEL...SLi instantaneous water heater.
Maximum loads of 80 °C / 1.0 MPa may
occur briefly in the installation in the
event of a fault. The plastic pipe system
used must be designed for such condi-
tions.
• A safety valve is not required.
• Never use valves for open systems!
Electrical installation:
• Electrical connection only to permanently
wired mains power cables
• The equipment must be able to be dis-
connected from the mains power supply,
for example by fuses that disconnect all
poles with at least 3 mm contact separati-
on.
15