7
Range of dial tone frequency (PABX):
6
000: 300Hz to 600Hz
5
001: 300Hz to 650Hz
010: 390Hz to 550Hz
011: 400Hz to 450Hz
100: 350Hz to 480Hz
101: 300Hz to 500Hz
110: Reserved
111: Reserved
4
Detection time to recognize as dial tone (PABX):
3
000: 2 sec.
2
001: 800 msec.
010: 400 msec.
011: 1 sec.
100: 1.3 sec.
101: 1.8 sec.
110: 2.5 sec.
111: 150 msec.
1
Allowable gap during line current detection (PABX):
0
00: Off
01: 50 msec.
10: 100 msec.
11: 200 msec.
<Remarks>
UAD 2 Bits 7 to 5:
Sets the range of the dial tone frequency that should be detected when calling through a PABX.
UAD 2 Bits 4 to 2:
Sets the time when the dial tone is recognized when calling through a PABX. When a dial tone is contin-
uously detected for the time specified in this setting, the facsimile regards the line as being connected.
UAD 2 Bits 1 and 0:
Set the allowable gap during line current detection when calling through a PABX. In line current detec-
tion, even if there are gaps within the time specified in this setting, the counter is not reset and contin-
ues to count the duration of line current detection after the current is re-detected.