FUNC 35
Bit
7
Receive Interval Setting:
6
0000 to 1111 counts up for each minute.
5
0000: 0 minute (=OFF)
4
0001: 1 minute
0010: 2 minutes
.
.
.
1110: 14 minutes
1111: 15 minutes
3
Undefined
2
Weekly timer
0: Off
1: On
1
Auto supplies order number
0: 1 order
1: 2 order
0
Ext. field bit comm. Function
0: comm
1: comm Err.
<Remarks>
FUNC 35 Bits 7 to 4:
This function insures, there will be a period of time set aside receiving incoming facsimiles during peri-
ods of heavy outgoing transmission activity. After every fourth consecutive transmission, this machine
will wait incoming facsimiles to be received.
FUNC 35 Bit 2:
Select enabling/disabling timer setup for days of the week.
FUNC 35 Bit 1:
Select the number of sets for supplies order. (0: 1 set, 1: 2 sets)
FUNC 35 Bit 0:
0: When the extended bit is on for the DIS or DTC signal and there is no subsequent bit information, the
communication is enabled, regarding the sequence up to the extend bit as valid.
1: When the extended bit is on for the DIS or DTC signal and there is no subsequent bit information, the
communication error will result.