4-3.

SERVICE MODE

Additional note on adjustment
Note: After the completion of the all adjustments, cancel the ser-
vice mode by either of the following ways.
1) After data on page: D is restored, press the RESET
button to reset the unit. (In this case, date and time and
menu setting have been set by users are canceled. Per-
form resetting)
2) After data on page: D is restored, select page: 0, ad-
dress: 01, and return the data to 00. And when data on
page: 2 and 3 are changed, return data to the original
condition.

1. Setting the Test Mode

Page D
Data
00
Normal
01
Forced camera power ON
02
Forced VTR power ON
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page D, the data set will be recorded in the non-volatile
memory by pressing the PAUSE button of the adjustment re-
mote commander. In this case, take note that the test mode will
not be exited even when the main power is turned off (8.4 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjust-
ment remote commander. And select page: 0, address: 01, and
set data: 00.
Address 10
Function

2. Emergence Memory Address

2-1. C Page Emergence Memory Address

Page C
Address
F4
EMG code when first error occurs
Upper: MSW code when shift starts when first error
F6
occurs
Lower: MSW code when first error occurs
Lower: MSW code to be moved when first error
F7
occurs
F8
EMG code when second error occurs
Upper: MSW code when shift starts when second
FA
error occurs
Lower: MSW code when second error occurs
Lower: MSW code to be moved when second error
FB
occurs
FC
EMG code when last error occurs
Upper: MSW code when shift starts when last error
FE
occurs
Lower: MSW code when last error occurs
Lower: MSW code to be moved when last error
FF
occurs
When no error occurs in this unit, data "00" is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (F4 to F7). In the same way, when the second error occurs,
the data corresponding to the error is written in the second emer-
gency address (F8 to FB).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (FC to FF).
Note: After completing adjustments, be sure to initialize the data
of addresses F4 to FF to "00".
Initializing method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: C, address: F4, set data: 00, and press the PAUSE
button.
3) Select address: F5 to FF and set data "00" into them in the
same way as address: F4.
4) Select page: 0, address: 01, and set data: 00.