Initialization Of 7, E, F; Initializing The 7, E, F; Modification Of 7, E, F; Page Table - Sony DCR-TRV140 Service Manual

Hide thumbs Also See for DCR-TRV140:
Table of Contents

Advertisement

1-2-2. INITIALIZATION OF 7, E, F PAGE DATA
1. Initializing the 7, E, F Page Data
Note1: If "Initialization of Pages 7, E, F" is executed, all data on
pages 7, E and F are initialized. (Only an individual page
cannot be initialized)
Note2: If the 7, E, F page data has been initialized, "Modifica-
tion of 7, E, F Page Data" and following adjustments need
to be performed again.
1) Camera system adjustments
2) "CAP FG duty adjustment" of the servo & RF system adjust-
ments
3) "27 MHz origin oscillation adjustment" of the video system
adjustment
Adjusting Page
7
Adjusting Address
00 to FF
Adjusting Page
E
Adjusting Address
00 to FF
Adjusting Page
F
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
1
0
01
01
2
6
00
55/51 (Note)
3
6
01
55/51 Press PAUSE button. (Note)
4
6
02
5
Note: NTSC model/PAL model
2. Modification of 7, E, F Page Data
If the 7, E, F page data has been initialized, change the data of the
"Fixed data-2" address shown in the following tables by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 7, E, F Page data
Order Page Address Data
1
2
00
29
2
2
01
29
3
0
01
00
Procedure
Check the data changes to
"01".
Perform "Modification of 7,
E, F Page Data"
Procedure
Press PAUSE button.
DCR-TRV140/TRV140E/TRV140M

3. 7 Page Table

Note1: Fixed data-1: Initialized data. (Refer to "1. Initializing
the 7, E, F Page Data")
Note2: Fixed data-2: Modified data. (Refer to "2. Modification
of 7, E, F Page Data")
Initial value
Address
NTSC PAL
00 to FF
5-11
Remark
Fixed data-1 (Initialized data)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trv140eTrv140m

Table of Contents