How To Operate The Unit; Maintenance; Specifications - JB Systems iMove 7S Operation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3
ENGLISH

HOW TO OPERATE THE UNIT

Every time you turn the unit on, it will show IM7S on the display and move all the motors to their 'home'
position and you may hear some noises for about 20 seconds. After that the unit will be ready to receive
DMX signal or run the built-in programs.
You can operate the unit in three ways:
o
By master/slave built-in preprogram function
By CA-8 easy controller
o
By universal DMX controller
o
 BY MASTER/SLAVE BUILT-IN PREPROGRAM FUNCTION:
Select this function when you want an instant show. By linking the units in master/slave
connection, the first unit will control the other units to give an automatic, sound
activated, synchronized light show. Its DMX input will have nothing plugged into it, and
its master-LED will be constantly on and sound-LED will flash to the music.
Important! This function only works when the blackout mode in the menu of the
master is set to OFF, otherwise nothing will happen! Read more about this
option in the "Main Menu" paragraph.
 MASTER has 4 built-in shows: You can select
(show 3) or
(show 4) directly in the menu of the master.
 SLAVES have 2 working options: The other units are set to slave mode (slave-
LED is constantly on). In order to create a great light show you can introduce
contrast movements (pan/tilt of slave is inversed)  In the menu of the slave units
you can go to option
and select:
 Normal slave: slave works in sync with the master.
o
 2 light show: slave works in opposite with the master.
o
 BY EASY CONTROLLER:
When used in Master/slave mode we strongly advice you to use the CA-8 "Easy controller" Just connect
this small controller to the 1/4" jack of the master unit, and you will be able to control the following
FUNCTIONS:
Stand by Blackout the unit
Strobe
X/Y moving
1.Gobo/Color
show mode
sync. strobe
selection
Function
( Show 1 ~ Show
2.Sync. strobe
4 )
3.Two-light
strobe
Sound 1
Sound 2
Mode
(LED off )
(LED normal
blinking)
JB SYSTEMS®
11/62
OPERATION MANUAL
(show 1),
(show 2),
Color/Gobo
X/Y moving setting
selection
1.Pan position
1. Hold on for
2.Tilt position
gobo change.
3.Dimmer
2. Press shortly
First set Master unit, then set Slave units'
for color
position.
change.
Slow/Sound 3
Position/ Latch
(LED on)
(LED fast blinking)
iMove 7S
ENGLISH

MAINTENANCE

 Make sure the area below the installation place is free from unwanted persons during servicing.
 Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
 All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
 Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
 When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
 In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
 The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
 Clean with a soft cloth using normal glass cleaning products.
 Always dry the parts carefully.
 Clean the external optics at least once every 30 days.
 Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!

SPECIFICATIONS

Mains Input:
Fuse:
Sound Control:
DMX connections:
Lamp:
Size:
Weight:
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com
JB SYSTEMS®
12/62
OPERATION MANUAL
AC 230V, 50Hz
6,3 A/250V
Internal microphone
3pin XLR male / female
HTI: 150 W
373 x 295 x 451 mm
13 kg
iMove 7S

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents