Table 10-1
Numeric Codes and Text Messages (continued)
Control panel message
2205-Interface error during MEBx execution
2211-Memory not configured correctly for
proper MEBx execution.
2212-USB Key Provisioning failure writing to
device
2217-ME Firmware Version request failure
2218-ME Firmware Version should be updated
2219-USB Key Provisioning file has invalid
header identifier
2220-USB Key Provisioning file has mismatch
version
2230-General error during MEBx execution
Description
MEBx operation experienced a hardware error
during communication with ME.
SODIMM1 or XMM1 is not installed.
USB device used for USB key provisioning will
not allow BIOS to update provision file properly.
ME firmware is not properly responding to BIOS
query for version information.
ME firmware must be updated to match current
functionality contained in the system BIOS.
Provisioning file contained on the USB key has
been corrupted or is not a valid version for the
current ME firmware.
Provisioning file contained on the USB key is not
a valid version for the current ME firmware.
Error occurred during MEBx execution which
fails into the "General" grouping. Status
information displayed along with the error
provides further clarity into the failure. MEBx
Recommended action
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace the
system board.
Make sure there is a memory module in the
black SODIMM1 socket and that it is properly
seated.
1.
Try a different USB key device for
provisioning.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Update to the latest ME firmware version.
2.
If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version.
3.
If the error still persists, replace the
system board.
1.
Recreate the provisioning file using third
party management console software.
2.
If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version. Otherwise, update
the ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version. Otherwise, update
the ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
POST Numeric Codes and Text Messages 107