Stinger II
Power Supply:
The ADJ Stinger II contains a automatic voltage
switch, which will auto sense the voltage when it is plugged into the
power source. With this switch there is no need to worry about the cor-
rect power voltage, this unit can be plugged in anywhere.
DMX-512:
DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of
communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA "IN" and DATA "OUT" XLR terminals located on all DMX
fixtures (most controllers only have a DATA "OUT" terminal).
DMX Linking: DMX is a language allowing all makes and models of
different manufactures to be linked together and operate from a sin-
gle controller, as long as all fixtures and the controller are DMX com-
pliant. To ensure proper DMX data transmission, when using several
DMX fixtures try to use the shortest cable path possible. The order
in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned a DMX address of 1
may be placed anywhere in a DMX line, at the beginning, at the end,
or anywhere in the middle. When a fixture is assigned a DMX address
of 1, the DMX controller knows to send DATA assigned to address 1
to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave
Operation): The Stinger II can be controlled via DMX-512 protocol.
The Stinger II is has 2 DMX channel modes, a 2 channel mode and 9
channel mode. The DMX address is set electronically using the con-
trols on the back panel of the unit. Your unit and your DMX controller
require a approved DMX-512 110 Ohm Data cable for data input and
data output (Figure 1). We recommend Accu-Cable
DMX cables. If you are making your own cables, be
sure to use standard 110-120 Ohm shielded cable
(This cable may be purchased at almost all pro-
fessional sound and lighting stores). Your cables
should be made with a male and female XLR con-
nector on either end of the cable. Also remember
that DMX cable must be daisy chained and cannot
be split.
ADJ Products, LLC - www.adj.com - Stinger II Instruction Manual Page 7
Set Up
Stinger II
Universal DMX Control:
sal DMX-512 controller to control the patterns, rotation and strobing.
A DMX controller allows you to create unique programs tailored to
your individual needs.
1. The Stinger II is a 2 DMX channel modes; a 2 channe mode and
9 channel mod. See pages 19-20 for detailed description of the
DMX values and traits.
2. To control your fixture in DMX mode, follow the set-up procedures
on pages 7-9 as well as the set-up specifications that are
included with your DMX controller.
3. Follow the instructions on page 12 to set the DMX address.
4. For longer cable runs (more than a 100 feet) use a terminator on
the last fixture.
5. For help operating in DMX mode consult the manual included
with your DMX controller.
Sound Active Mode:
linked together, to run to the beat of the music.
1. Press the MENU button until "Soun" is displayed, and press
ENTER.
2. Press the UP or DOWN buttons to either activate sound active
mode or deactivate, and press ENTER. The unit will now run to
the beat of the music.
3. The sound sensitivity can be adjusted by pressing the MENU
button until "Sose" is displayed, and then press ENTER. Use the
UP or DOWN buttons to adjust the sound sensitivity, 0 being the
least sensitive, and 99 being the most sensitive.
Show Mode:
together, to run to a built-in program.
1. Press the MENU button until "Shnd" is displayed, and press
ENTER.
2. Press the UP or DOWN buttons to find your desired show and
press ENTER. The unit will now run your chosen built-in program.
Figure 1
ADJ Products, LLC - www.adj.com - Stinger II Instruction Manual Page 16
This function allows you to use a univer-
This mode allows a single unit or several units
This mode allows a single unit or several units linked

Operation

Hide quick links: