Advertisement

SABER SPOT GO
User Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SABER SPOT GO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADJ SABER SPOT GO

  • Page 1 SABER SPOT GO User Instructions...
  • Page 2 All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their respective companies. ADJ Products, LLC and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic...
  • Page 3: Table Of Contents

    WiFly Set Up I WiFly Master-Slave I Runtime Mode ADJ UC IR/Airstream IR Control Dimmer Curve Chart Dimensional Drawings Frost Filter Installation I Trouble Shooting I Cleaning Limited Warranty (USA Only) Specifications ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 2...
  • Page 4: Introduction

    DMX cables. Saber Spot GO can operate as a stand alone fixture or in a Master/Slave set up. The Saber Spot GO has three operating modes;...
  • Page 5: Features I Warranty Registration

    Saber Spot GO Warranty Registration The Saber Spot GO carries a 2 year (730 Days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package.
  • Page 6: Safety Guidelines

    A. Objects have fallen, or liquid has been spilled into the appliance. B. The appliance has been exposed to rain or water. C. The appliance does not appear to operate normally or exhibits a marked change in performance. ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 5...
  • Page 7: Battery Precautions

    DO NOT use the battery. A battery with a odor of electrolyte or a gel leakage should be placed away from fire to avoid fire or explosion. ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 6...
  • Page 8 When the unit reaches full charge the charging indicator will glow green. It takes about 4 hours to reach full charge. ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 7...
  • Page 9: Installation I Safety Strap

    NOTE: This unit comes with 2 velcro safety straps. It is highly suggested that both straps are used to properly secure the unit. Velcro Strap Velcro Strap ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 8...
  • Page 10: Overview

    Saber Spot GO Overview SAFETY CABLE RIGGING POINT POWER POWER IN SWITCH CHARGING LCD DISPLAY INDICATOR CONTROL PANEL (MODE/UP/DOWN/ENTER) MAGNETS ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 9...
  • Page 11: Dmx Addressing

    In the case of the Saber Spot GO, when in 4 Channel you should set the starting DMX address of the first unit to 1, the second unit to 5 (4 + 1), the third unit to 9 (5 + 4), and so on. (See chart below for more details.)
  • Page 12: Dmx Modes

    0-100% SATURATION 000-255 0-100% MASTER DIMMER 000-255 0-100% DIMMER FINE 000-255 0-100% INTENSITY 000-255 0-100% COLOR MACROS 000-255 PLEASE SEE THE COLOR MACRO CHART ON PAGES 13-14 ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 11...
  • Page 13 AUTO PROGRAM SPEED 000-255 SLOW-FAST AUTO PROGRAM FADE SPEED 000-255 FAST-SLOW DIMMER CURVES 000-020 STANDARD 021-040 STAGE 041-060 061-080 ARCHITECTURAL 081-100 THEATRE 101-255 DEFAULT TO UNIT SETTING ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 12...
  • Page 14: Color Macro Chart

    Color56 Color24 93-96 Color57 Color25 97-100 Color58 Color26 101-104 Color59 Color27 105-108 Color60 Color28 109-112 Color61 Color29 113-116 Color62 Color30 117-120 Color63 Color31 121-124 Color64 Color32 125-128 ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 13...
  • Page 15 201-204 Color52 205-208 Color53 209-212 Color54 213-216 Color55 217-220 Color56 221-224 Color57 225-228 Color58 229-232 Color59 233-236 Color60 237-240 Color61 241-244 Color62 245-248 Color63 249-252 Color64 253-255 ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 14...
  • Page 16: System Menu

    Temp Val Temperature Value: XXX F AUTOLOCK AUTOLOCK OFF/ON IR Active IR Active OFF/ON FlipDisplay Flip Disply OFF/ON WiFly Channel CH: 00-14 Fixture Power XXX% Runtime Mode 2/4/6/8 ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 15...
  • Page 17: Operating Instructions

    4. Press the UP or DOWN buttons to continue to adjust the colors. To activate strobing, return to the strobe setting and follow the values listed under “Shutter & Strobing” in DMX control on page 10. ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 16...
  • Page 18 1. Press either the MODE, UP, or DOWN buttons until “Temp Val” is displayed, and press ENTER. 2. The fixture temperature will now be displayed. Press the MODE button to exit. ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 17...
  • Page 19 1. Press either the MODE, UP, or DOWN buttons until “Runtime Mode” is displayed, and press ENTER. 2. Press the UP or DOWN buttons to find your desired dimmer curve and press ENTER to confim ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 18...
  • Page 20: Wifly Set Up I Wifly Master-Slave I Runtime Mode

    Saber Spot GO WiFly Set Up This unit can only be controlled using WiFly. Your DMX controller must be connected to a ADJ WiFly Transceiver to use this function. You are able to communicate up to 2500 feet/760 meters (open line of sight).
  • Page 21: Adj Uc Ir/Airstream Ir Control

    The ADJ UC IR (not included) infrared remote gives you control of various functions (See below). To control the Saber Spot GO you must aim the remote at the front of the fixture and be no more than 30 feet away. To use the ADJ UC IR you must first activate the fixtures infrared sensor, to activate the sensor please see the instructions on page 18.
  • Page 22: Dimmer Curve Chart

    Down Time (ms) Rise Time (ms) Down Time (ms) Standard (default) Stage 1100 1540 1660 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 21...
  • Page 23: Dimensional Drawings

    Saber Spot GO Dimensional Drawing 6.8” / 172mm 5” / 127mm 6.3” / 160mm 3.9” / 100mm ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 22...
  • Page 24: Frost Filter Installation I Trouble Shooting I Cleaning

    Frost Filter Installation The Saber Spot GO comes with 2 frost filters. Before installation, peel off the adhesive backing on both sides of the lens. Install the frost filter in front of the main lens (1 & 2). Insert the inlcuded retainer ring by “squeezing”...
  • Page 25: Limited Warranty (Usa Only)

    ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because not properly maintained as set forth in the instruction manual.
  • Page 26: Specifications

    **See Warranty page for more details Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. ADJ Products, LLC - www.adj.com - Saber Spot GO User Manual Page 25...

Table of Contents