Program The Length Range (Maximum/Minimum Lengths) For A Symbology; Program The Custom Inter-Keystroke Delay - Newland HR22 Dorada User Manual

Handheld barcode scanner
Table of Contents

Advertisement

m. Program the Length Range (Maximum/Minimum Lengths) for a Symbology
Note: If minimum length is set to be greater than maximum length, the scanner only decodes barcodes
with either the minimum or maximum length. If you only want to read barcodes with a specific length, set
both minimum and maximum lengths to be that desired length.
Example: Set the scanner to decode Code 128 barcodes containing between 8 and 12 characters
1.
Scan the Enter Setup barcode.
2.
Scan the Set the Minimum Length barcode. (See the "Set Length Range for Code 128" section
in Chapter 7)
3.
Scan the numeric barcode "8".
4.
Scan the Save barcode.
5.
Scan the Set the Maximum Length barcode. (See the "Set Length Range for Code 128" section
in Chapter 7)
6.
Scan the numeric barcodes "1" and "2".
7.
Scan the Save barcode.
8.
Scan the Exit Setup barcode. (If you still need to program other parameter/feature, skip this step.)
n. Program the Custom Inter-keystroke Delay
Example: Set the inter-keystroke delay to 15ms
1.
Scan the Enter Setup barcode.
2.
Scan the Custom Delay barcode. (See the "Inter-Keystroke Delay" section in Chapter 2)
3.
Scan the numeric barcodes "1" and "5".
4.
Scan the Save barcode.
5.
Scan the Exit Setup barcode. (If you still need to program other parameter/feature, skip this step.)
152

Hide quick links:

Advertisement

Table of Contents
loading