SPECIFICATIONS & CLEARANCES FOR TOP VENTING
WARNING: Do not cover the 2" faceplate border of the unit with combustible materials.
6"MIN.
1"MIN.
10
"
45°
Adjacent Walls:
A wall, perpendicular to and in front of the appliance front
facing must be at least 10" from the firebox opening. A
wall at 45° to the front and starting at the appliance's
outer edge is permitted. Projections behind this wall (shaded
area) are permitted.
14 MIN.
FROM TOP
OF GRILL
TO 8" MANTEL
40 7/8
IF MANTEL IS MADE OF A NON-COMBUSTIBLE MATERIAL
(BRICK, STONE, ETC..), OR HAS A STEEL PROTECTOR PLATE
ON THE UNDERSIDE IT MAY BE PLACED ANYWHERE ABOVE GRILL
NOTE
: For L.P. & High Altitude (above 4,000 ft. but below 7500 ft.), 45º elbows must be used in place of 90º
elbows (see pg. 15 FOR
MENDOTA TECHNICAL HOTLINE FOR FURTHER INFORMATION ON THE STRICT
REQUIREMENTS FOR INSTALLATIONS AT THESE ALTITUDES.
o
Using 45
elbows requires 19" minimum opening to center (see page 15 CAUTION: If 90ºelbows must be used with LP
or at high altitudes, a 3-foot vertical starter section must be used directly off the top of the fireplace.
MENDOTA DXV-35 GAS DIRECT VENT FIREPLACE
22 1/4
11 1/8
4 1/2
35 7/8
1/2 TO
2 1/2
MINIMUM FRAMING DIMENSIONS
FOR THE DIRECT VENT
31-1/2
HEIGHT
(800 mm)
37 1/8
WIDTH
(943 mm)
16
DEPTH
(407 mm)
8" COMBUSTIBLE MANTEL
32
Figure 4: Specifications & Clearances
INSTALLATION AT ALTITUDES ABOVE 7,500 FEET, FIRST CALL
26 1/4
15 3/8
1
8" MANTEL
DEPTH (WIDTH)
14" MANTEL
HEIGHT FOR
8" MANTEL
MIN. 9"
SECTION
31 1/2
29
NON-COMBUSTIBLE
HEARTH PROTECTOR
REQUIRED
1 7/8
NOTE:
FOR EVERY 1" THE FIREPLACE IS RAISED OFF THE FLOOR,
HEARTH PROTECTOR MAY BE REDUCED BY 2".
IF FIREPLACE IS RAISED 6" OR MORE, NO HEARTH PROTECTION IS REQUIRED.
12
37 1/8
10 3/4
52 1/2
MUST REMAIN IN THIS
COMBUSTIBLE MANTEL
TRIANGULAR AREA. FOR
EVERY 1" INCREASE IN
MANTEL DEPTH, INCREASE
HEIGHT ABOVE GRILL
BY 2". MANTEL MAY BE LOWERED
DECREASED IN THE SAME MANNER
2
2" MIN.
1"
MIN.
4 5/8
GAS INLET
2 1/2
85-03-00458
12
IF DEPTH IS
16 1/4 MIN.
FROM TOP
OF UNIT
TO STACK
CENTER
49 1/2" MIN.
CLEARANCE TO
COMBUSTIBLE
ABOVE UNIT
& MINIMUM
CEILING HEIGHT