Specifications & Clearances - Mendota DXV-35 DT3 - LX Installation & Operating Instructions Manual

Gas direct vent fireplace with premium texture fiber logs combustion system
Table of Contents

Advertisement

outage, turn off the burners for 1 hour and allow the fireplace to cool down. Consecutive 1-1/2 hour burn and 1 hour cool
down cycles are allowed. On LOW FIRE (front burner only), you may operate continuously during power outage.
SPECIFICATIONS & CLEARANCES
WARNING
: Do not cover the 2" faceplate border of the unit with combustible materials.
6"MIN.
1"MIN.
10
"
45°
Adjacent Walls:
A wall, perpendicular to and in front of the appliance front
facing must be at least 10" from the firebox opening. A
wall at 45° to the front and starting at the appliance's
outer edge is permitted. Projections behind this wall (shaded
area) are permitted.
31 7/16
41
27
IF MANTEL IS MADE OF A NON-COMBUSTIBLE MATERIAL
(BRICK, STONE, ETC..), OR HAS A STEEL PROTECTOR PLATE
ON THE UNDERSIDE IT MAY BE PLACED ANYWHERE ABOVE GRILL
NOTE: For L.P. & High Altitude (above 4,000 ft. but below 7500 ft.), 45º elbows must be used in place of 90º elbows
Installation At Altitudes Above 7,500 Feet, First Call Mendota Technical Hotline For Further Information On The Strict Re-
quirements For Installations At These Altitudes.
CAUTION: If 90ºelbows must be used with LP or at high altitudes, a
directly off the top of the fireplace.
MENDOTA DXV-35 GAS DIRECT VENT FIREPLACE
22 5/16
11 1/8
35 7/8
1/2 TO
2 1/2
MINIMUM FRAMING DIMENSIONS
FOR THIS FIREPLACE
31-1/2
HEIGHT
(800 mm)
37 1/8
WIDTH
(943 mm)
16
DEPTH
(407 mm)
8" COMBUSTIBLE MANTEL
36 1/4 TO SCREW HEADS
28 3/8
32 5/8
16 1/16
1 15/16
Figure 4: Specifications & Clearances
26 1/2
4 1/2
15 3/8
8" MANTEL
DEPTH (WIDTH)
14" MANTEL
14
HEIGHT FOR
8" MANTEL
31 11/16
NON-COMBUSTIBLE
HEARTH PROTECTOR
REQUIRED
NOTE:
FOR EVERY 1" THE FIREPLACE IS RAISED OFF THE FLOOR,
HEARTH PROTECTOR MAY BE REDUCED BY 2".
IF FIREPLACE IS RAISED 6" OR MORE, NO HEARTH PROTECTION IS REQUIRED.
2-foot vertical starter section must be used
16
37 7/16
10 3/4
52 1/2
MUST REMAIN IN THIS
COMBUSTIBLE MANTEL
TRIANGULAR AREA. FOR
EVERY 1" INCREASE IN
MANTEL DEPTH, INCREASE
HEIGHT ABOVE GRILL
1
BY 2". MANTEL MAY BE LOWERED
DECREASED IN THE SAME MANNER
2
2" MIN.
1"
MIN.
4 21/32
GAS INLET
2 7/16
85-03-00458
12
16 1/4
IF DEPTH IS
16 1/4 MIN.
FROM TOP
OF UNIT
TO STACK
CENTER
52 1/2" MIN.
CLEARANCE TO
COMBUSTIBLE
ABOVE UNIT
& MINIMUM
CEILING HEIGHT
. For

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxv-35 dt3-lx

Table of Contents