Menu 5 - Service - Nibe F370 Installer Manual

Hide thumbs Also See for F370:
Table of Contents

Advertisement

Menu 5 - SERVICE

5 - SERVICE
* Accessory needed.
Hold the Back button in for 7 seconds to access the
Service menu.
Sub-menus
Menu
SERVICE
has orange text and is intended for
the advanced user. This menu has several sub-menus.
Status information for the relevant menu can be found
on the display to the right of the menus.
operating settings
Operating settings for the heat
pump.
system settings
System settings for the heat pump,
activating accessories etc.
accessory settings
Operational settings for different
accessories.
soft in/outputs
Setting software controlled in and
outputs on the input circuit board (AA3).
factory setting service
Total reset of all settings (includ-
ing settings available to the user ) to default values.
forced control
Forced control of the different compon-
ents in the heat pump.
start guide
Manual start of the start guide which is
run the first time the heat pump is started.
quick start
Quick starting the compressor.
NOTE
Incorrect settings in the service menus can
damage the heat pump.
Menu 5.1 - operating settings
Operating settings can be made for the heat pump in
the sub menus.
NIBE™ F370
5.1 - operating settings
5.2 - system settings
5.3 - accessory settings
5.4 - soft in/outputs
5.5 - factory setting service
5.6 - forced control
5.7 - start guide
5.8 - quick start
5.9 - floor drying function
5.10 - change log
Overview
5.1.1 - hot water settings
5.1.2 - max flow line temperat-
ure
5.1.4 - alarm actions
5.1.5 - fan sp. exhaust air
5.1.12 - internal electrical addi-
tion
5.1.99 - other settings
5.2.4 - accessories
5.3.3 - extra climate system *
Menu 5.1.1 - hot water settings
economy
Setting range start temp. economy: 15 – 52 °C
Factory setting start temp. economy: 45 °C
Setting range stop temp. economy: 15 – 55 °C
Factory setting stop temp. economy: 51 °C
normal
Setting range start temp. normal: 15 - 52 °C
Factory setting start temp. normal: 49 °C
Setting range stop temp. normal: 15 - 55 °C
Factory setting stop temp. normal: 55 °C
luxury
Setting range start temp. lux: 15 – 62 °C
Factory setting start temp. lux: 52 °C
Setting range stop temp. lux: 15 – 65 °C
Factory setting stop temp. lux: 58 °C
stop temp. per. increase
Setting range: 55 – 70 °C
Default values: 60 °C
Here you set the start and stop temperature of the hot
water for the different comfort options in menu 2.2 as
well as the stop temperature for periodic increase in
menu 2.9.1.