Using An External Flue; Prevention Of Domestic Fires - Piazzetta P958 Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

1.11 USING AN ExTERNAL FLUE

An external flue can be used provided it complies with the following
requirements:
- use only insulated stainless steel pipes (double-lined) fixed to the
outside wall of the building (Fig. 23);
- there must be an inspection opening at the base of the flue to permit
periodic checks and maintenance;
- the flue must be fitted at the top with a chimney stack with down-
draught cowl, also ensuring compliance with the safety distance from
the roof ridge as outlined in the section entitled "CHIMNEY STACK".
a
Ensure that all installation work is carried out to professional
standards.

1.12 PREvENTION OF dOMESTIC FIRES

The product must be installed and used in compliance with the manufacturer's instructions and European and national standards as well as local
regulations.
a
When a flue pipe passes through a wall or a ceiling, special installation methods must be applied (protection, thermal insulation,
distances from heat-sensitive materials, etc.) See the paragraph "CONNECTING TO A CONVENTIONAL CHIMNEY".
• It is also recommended that all elements made of combustible or inflammable material, such as beams, wooden furniture, curtaining, flammable
liquids, etc. be kept outside the heat radiation range of the stove and at a distance of at least 80 cm from the heating block.
• For other information, see the paragraph "MINIMUM SAFETY DISTANCES" and "CONNECTING TO A CONVENTIONAL CHIMNEY".
• The flue pipe, chimney stack, chimney and fresh air intake must always be free of obstructions, clean and checked periodically, that is, at least
twice during the seasonal period from the lighting of the stove and during its use. When the stove has not been used for some time it is advisable
to carry out the checks mentioned above. For further information, consult a chimneysweep.
• Only use recommended fuels (See section "FUEL").
12
Fig. 23
H07026300 / DT2000786 – 00
DT2010232-02
d
FRESH AIR INTAKE WITH
NON-CLOSABLE GRILLE
DT2030341-00
DT2010027-02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents