Troubleshooting - Piazzetta P958 Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

8.0 TROUbLEShOOTING

a
Some of the problems indicated below may be resolved by following the instructions. All work must be carried out when the appliance
is cold and disconnected from the electricity supply (pull out the plug).
a
Authorised qualified persons must be contacted, in accordance with current regulations, whenever it is necessary to work on parts
inside the cladding or the firebox in order to resolve the problem.
It is therefore recommended that only "Gruppo Piazzetta S.p.A." authorised Service Centres be contacted.
Whenever authorised Service Centre personnel carry out work, they must show an identity card issued by Gruppo Piazzetta S.p.A.
on which the following are printed: name of the Service Centre, stamp and signature of the company and the period of validity of the
actual document.
a
Unauthorised tampering with the appliance or the use of other than original spare parts not only creates situations of risk for operator
safety, but invalidates the warranty and relieves the manufacturer from all liability.
Problem
The control panel display is not lit
Stove combustion gas safety device
"ALF 1" stove status
Cause
The appliance is not powered
Faulty power cable
Fuses blown
Faulty control panel
Faulty flat cable
Faulty electronic board
Blocked flue or flue gas outlet
Door open
Broken smoke extractor
Flue system too long
Damaged door sealing gaskets
Hose connection blocked
Silicone piping blocked or broken
Faulty electronic board
H07026300 / DT2000786 – 00
DT2011179-02
Solution
Check that the power cable is plugged
into the wall socket and connected to
the appliance
Replace the power cable (use only
original spares)
Check the fuses in both the plug and
the electronic board, replacing them if
necessary. If the problem persists call
an electrician
Replace the control panel (use only
original spares)
Replace the flat cable (use only
original spares)
Replace the electronic board (use only
original spares)
Check and clean the flue and the
outlet
Control if the door is closed
Replace the motor (use only original
spares)
Check correct installation
Check all the gaskets and seals of the
door and flue pipe
Dismantle and clean the hose
connection for the vacuum gauge
Check and/or replace piping
Replace the electronic board (use only
original spares)