Grounding the EdgePoint
Note:
The ground wire should be as short as possible and
no longer than one meter in length.
1. Remove the nut from the Ground Bonding Point located on the
back of the EdgePoint.
2. Attach a ground wire (min. 10 AWG or 5 mm
replace the nut to secure the wire.
3. Secure the other end of the ground wire to a grounded mast,
pole, tower, or grounding bar.
Grounding the EdgePoint
) to the lug and