KEYPAD CONFIGURATION MODE

This section will focus on configuring the GEM-RP2ASe2/GEM-K2AS, GEM-RP3DGTL/GEM-K3DGTL and GEM-
RP4RFC/GEM-K4RF Keypads. For ease of programming, it is recommended that a GEM-RP1CAe2 or a GEM-K1CA
be selected (see WI1386 for Programming Instructions using the GEM-RP1CAe2 or GEM-K1CA keypads).

KEYPAD INSTALLATION

Each keypad must be assigned an address number (1–7) and each requires its own configuration procedure (see
CONFIGURING THE KEYPADS, which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1
keypad must be used; only 1 is required for a single-area Commercial Burglary installation.
GEM-RP2ASe2/GEM-K2AS - are utility LCD keypads combining several preset LCD words with a limited
message line.
NOTE:
automatically.

CONFIGURING THE KEYPADS

Configuring the GEM-RP2ASe2/GEM-K2AS, GEM-RP3DGTL/GEM-K3DGTL and GEM-
RP4RFC/GEM-K4RF Keypads
Up to 7 GEM-RP2ASe2/GEM-K2AS, GEM-RP3DGTL/GEM-K3DGTL and/or GEM-RP4RFC/GEM-K4RF keypads may
be connected to the panel (Keypads 1–7). Each must be configured for a keypad address. In addition, the keypad may
be configured to disable (a) touchpad backlight; (b) LCD backlight; and
(c) entry sounder. Keypads are configured by the proper selection of
jumpers. Refer to the label on the circuit board insulation paper for
jumper locations and a summary of settings.
KEYPAD ADDRESS
If more than one keypad is installed:
Each must be assigned a unique address (that is, no two keypads
may be numbered alike).
Keypads must be addressed consecutively (that is, missing
numbers are not permitted).
Assign the keypad address number by selecting Jumpers J1–3 in
accordance with the table at right.
TOUCHPAD BACK LIGHT
Cut Jumper A to disable touch pad backlighting to conserve 11mA standby current.
LCD BACKLIGHT
Cut Jumper B to disable LCD backlighting.
DISABLE SOUNDER
Cut Jumper C to disable the sounder.
L
NAPCO Security Systems
Due to space constraints, available messages are abbreviated and will scroll
KEYPAD
NUMBER
1
1
OFF or
ON
OFF
2
3
ON
OFF
4
5
ON
OFF
6
7
ON
X
GEM-P1664EX Programming Instructions
Page 55
KEYPAD ADDRESS SETTING
2
3
PARK
OFF OFF
OFF
ON
STORE SPARE
ON
OFF
JUMPER AT THIS
OFF OFF
POSITION
OFF
ON
ON
ON
ON
ON