USER OPTIONS
USER CODE
AREA 1
AREA 2
OPTIONS
OPTIONS
(UP TO 6 DIGITS)
AREA OPTIONS
Disabled
User Code not active in this area.
Arm/Disarm
Allows User Code to arm/disarm this area.
Arm Only
Prevents User Code from disarming this area.
Service
A Service Code has restricted arm/disarm rights; if an area is armed with a
Service Code, a "MONITOR ON" appears on the GEM-RP2ASe2 keypad and the area
can be disarmed with any valid User Code, including a Service Code. If the area is
armed with OTHER than a Service Code, it CANNOT be disarmed with a Service
Code. This is typically used to allow tradesmen access to premises under control
of the owner.
Access
This is normally used to activate a door strike while an area is disarmed. Also
program "Access Control on PGM2 Output" (Address 0719) and "PGM2 Output
Access Control Timeout" (Address 0711).
There are two types of Ambush Codes: (1) A 2-digit code (prefix) that is entered
Ambush
immediately prior to (and as part of) the regular User Code and (2) A separate and
unique User Code. Disarming with an Ambush Code will cause a silent report to be
sent to a central station. Thus, should a user be forced to disarm, he can silently signal
an emergency while appearing to be merely disarming the system.
* User Program
User Program Option is enabled for Keypad 1 only, wherever it is connected (Area
1 or Area 2). To enable User Program Option for any user add 8 to the data entry
for Area 1 Option (see example). Then, User Programming can be performed only
at Keypad 1 by a user code with user program enabled.
Bypass Enable
Security Bypass--Bypass is enabled only with a security code.
CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above and press
U
to save. Similarly, to cancel a code, blank out each number of the code press
RF Transmitter Points (Press the (
Zn# 01
(For wireless systems only. Also see Quick Method, which follows)
For each transmitter (key fob transmitters also), enter the zone number (01–64) to which the transmitter
000000
will be mapped, the 6-digit RF ID #:1-digit checksum number printed on the transmitter and box, the
point number (1–2); enter "9" for unsupervised (all points). NOTE: When programming the ID Code
number, "0" through "9" =
(Direct Entry)
G 2
:0 Pt
save. Press the NEXT/YES button button to proceed.
(Direct Entry)
Quick Enroll Method.
If a receiver is already installed in the panel, Napco transmitter
wireless points can be programmed automatically ("enrolled")
using the following procedure. NOTE: The transmitter point will
be enrolled only if the signal strength is 3 or greater.
1. Enter the zone number to which the transmitter point will be
mapped.
2. Press the
button to enter the Enroll Mode. The red and
B
green LEDs on the keypad will flash.
3. Open the loop of the point that is to be programmed (GEM-
TRANS2 only).
4. Install the transmitter battery. The keypad will beep to indicate
that the point has been successfully enrolled.
transmitters
can
be
simultaneously (see example).
X
GEM-P1664EX Programming Instructions
USER AREA OPTIONS
AREA 3
AREA 4
DATA ENTRIES
OPTIONS
OPTIONS
L
blank(•)
blank(•)
blank(•)
blank(•)
blank(•)
blank(•)
blank(•)
4
EXPLANATION
0
; "D" =
G 3
Multi-point
mapped
to
successive
AREA OPTIONS: Area 1-4 Options may be
programmed for all 64 users.
OPTION
ENABLED
R
blank(•)
Disabled
1
Arm/Disarm
2
Arm Only
3
Service
4
Access
Example: Program a code of "2222" for user 02, with
5
Ambush
area 1 options of "Arm/Disarm" and "User Program".
Add 8
* User Program
Enter "2222" for a user code, "•(blank) 9" for area 1
blank(•)
Bypass Enable
options and "•(blank) •(blank)" for area 2 options.
For Area 2-4 Options (ACC), press
again.
options. NOTE: Press
Press
Code, press
Number and change it using the number buttons.
Program a new User Code as previously described.
Remember to record your user codes in the Easy
Menu Programming Worksheet at the back of this
manual.
Related User Options:
Code" (Address 1422), "Global Ambush Code" (Address
2045) & "Enable Manager's Mode" (Address 1421).
U
R
) button to set cursor.)
through
9
; "A" =
G 0
; "E" =
G 4
Example. A 2-point transmitter has the RF ID number 287613:1.
Map point 1 to Zone 6 and point 2 to Zone 9.
1. Enter the Enroll mode as described above.
2. Enter Zone "06".
3. Open point-1 loop.
4. Install the battery. The keypad will beep once to indicate that
one point has been programmed. (Transmitter 287613:1, point
1 will be mapped to Zone 6).
5. Enter Zone "09".
6. Close point-1 loop and open point-2 loop.
7. Remove the transmitter battery, then re-install it. The keypad
will beep once to indicate that one point has been
programmed. (Transmitter 287613:1, point 2 is mapped to
zones
Zone 9).
WI1387 7/05
Select the desired Area Options (Area 1-4)
from the table shown and enter in the
remaining four boxes for each user code.
Refer to the table above for available
for blank space (•).
0
U
to save. To proceed to the next User
to set the cursor to the User
R
"Enable Global Ambush
to save.
; "B" =
G 1
and "F" =
G 5
. Press
L
NAPCO Security Systems
A
; "C" =
U
to