Advertisement

8 ft 8 in
( 220 cm )
20 ft.
( 508 ) cm
8 ft 8 in
( 220 cm )
Fig. 3
18
4 ft. x 6 ft.
(101.6 x 152 cm)
Work table on wheels
Electrical cord
drop
Back
3 ft
( 91 cm )
Front
4 ft. x 6 ft.
(101.6 x 152 cm)
Work table on wheels
13 ft
( 330 cm )

PRE-INSTALLATION

Before a Talon 44/ 64 Laminator
can be installed, ensure the
following requirements are met;
1. Are door ways and hallways
wide enough for the laminator to
be moved to the installation site?
2. Is there ample room for the
laminator?
– A work area must be
established that allows for
operation in both the front and
rear of the laminator and
provides space for efficient
material flow. (Figure 3)
3. Is the environment appropriate
for the laminator?
– The laminator requires a clean,
dust and vapor free environment
to operate properly.
– Avoid locating the laminator
near sources of heat or cold.
Avoid locating the laminator in
the direct path of forced, heated
or cooled air.
CAUTION: Air flow can cause
uneven heating/ cooling of the
rollers and result in poor
output quality.
4. Have you contacted a certified
electrician to wire the receptacle
and ensure that adequate
power is being supplied, having
the appropriate capacity, over
current protection and safety
lockouts available?
Talon 44 requires:
– 220V at 60hz with 14.3 amp
service. Use a Nema 6-20R.
Talon 64 requires:
– 220V at 60hz with 15 amp
service. Use a Nema 6-20R.