3. Adjusting the Paper Feed Path

1.
Insert a thickness gauge [3] between the tear bar base [1]
and cutter guide [2] to measure the gap.
2.
The standard value for the gap is 0.3 to 0.5 mm. If the
adjustment is within that range, tighten the screws [4]
you loosened or removed.
[ 1 ]
Fig. 3-1 Measuring the Gap
[ 4 ]
Fig. 3-2 Where to Measure the Gap
-  -
[ 3 ]
[ 2 ]
[ 4 ]
[ 1 ]
[ 2 ]