5.5.3
Adjusting the Gap Sensor Level Manually
The adjustment procedure for the Gap sensor level is as follows:
1
Go to the SENSOR LEVEL setting screen
of SERVICE MODE.
Perform steps 1 through 4 of
Adjusting the Media Sensor
2
Select MANUAL using the
and then press the
SENSOR SELECT shows on the screen.
3
Press the
buttons to select GAP and
/
then press the
The light emission level adjustment of the Gap
sensor is shown.
4
On the SENSOR LEVEL GAP(E) screen,
press the
buttons to set ADJUST
/
LEVEL to 2 and then press the
button.
The adjustment range of ADJUST LEVEL is from 0
to 3.
We recommend using the initial value which is 2.
The light reception level adjustment of the Gap
sensor is shown.
First, adjust the "Low" reception level (voltage) of the Gap sensor.
5
Open the top cover and unlock the media
feed and media sensor assembly .
6
Physically place the liner without the
label resting over the Gap sensor.
7
Press the media feed and media sensor
assembly down to lock it.
To get the correct adjustment result, close the
media sensor assembly before performing the
adjustment.
Section 5.5.1
Automatically.
buttons
/
ENTER button.
ENTER button.
ENTER
5 Cleaning and Performing Printer Adjustments
1
2
S84-ex/S86-ex Operator Manual
Gap sensors
area
191