Applying Power; Enrolling The Keypad - DSC LCD55O1Z32-433 Installation Manual

Table of Contents

Advertisement

I
N

1.4 Applying Power

Once all wiring is complete, apply power to the control panel:
1. Connect the battery leads to the battery.
2. Connect the AC transformer.
For more information on control panel power specifications, see the control panel
Installation Manual .
NOTE: Do not connect the power until all wiring is complete.

1.5 Enrolling the Keypad

Once all wiring is complete, you will need to enter a 2-digit number that tells the
system the partition and slot assignment of the keypad.
If your system has partitions, you will also need to assign the keypad to a partition
(1st digit).
The slot assignment (2nd digit) tells the panel which keypad slots are occupied. The
panel can then generate a fault when a keypad supervisory signal is not present.
There are eight available slots for keypads. LCD5501Z32-433 keypads are always
assigned to slot 1 by default. You will need to assign each keypad to its own slot (1
to 8).
NOTE: The LCD5501Z32-433 enrolls as two modules:
1 = keypad section of the LCD5501Z32-433
17 = receiver section of the LCD5501Z32-433
Enter the following at each keypad installed on the system:
1. Enter Installer Programming by pressing [*][8][Installer's Code]
2. Press [000] for Keypad Programming
3. Press [0] for Partition and Slot Assignment
4. Enter a two digit number to specify the partition and slot assignment.
NOTE: If your system does not have partitions, enter [1] for the first digit.
1st digit
2nd digit
5. Press the [#] key twice to exit programming.
6. After assigning all keypads, perform a supervisory reset by entering [*][8][Installer's
Code][902]. The panel will now supervise all assigned keypads and enrolled
modules on the system.
To review which modules the control panel is currently supervising:
1. Enter [ ][8][Installer's Code]
2. Enter [903] to display all modules. On the LCD5501Z32-433 keypad, 1 1 1 1 1 and 1 1 1 1 1 7 7 7 7 7 will
scroll on the keypad to indicate that the LCD5501Z32-433 is present on the system. 1 1 1 1 1
designates the keypad section, and 17
supervised. If using an LCD5501Z keypad, scroll until the module name appears on
the display.
3. To exit press [#].
S
T
A
Enter 0 for Global Keypad
Enter 1 for Partition 1 Keypad
Enter 2 for Partition 2 Keypad
Enter 1 to 8 for Slot Assignment
L
L
A
17 is used to show the receiver section is also
17
17
17
3
T
I
O
N

Hide quick links: