Applying Power; Enrolling The Keypad - DSC RF55O1-433 Installation Manual

Table of Contents

Advertisement

I
N
4. Each PGM output is an open collector switch to ground. That is,
when the PGM output is activated by the RF5501-433 the terminal
will switch to ground. P1 can sink up to 50 mA of current to activate
LEDs or a small buzzer. Connect the positive side of the LED or
buzzer to AUX+, the negative side to P1. If more than 50 mA of
current is required a relay must be used. Please refer to diagram.

1.4 Applying Power

Once all wiring is complete, apply power to the control panel:
1. Connect the battery leads to the battery.
2. Connect the AC transformer.
For more information on control panel power specifications, see the control panel
Installation Manual .
NOTE: Do not connect the power until all wiring is complete and unit is securely mounted.

1.5 Enrolling the Keypad

Once all wiring is complete, you will need to enter a 2-digit number that tells the
system the partition and slot assignment of the keypad.
If your system has partitions, you will also need to assign the keypad to a partition
(1st digit).
The slot assignment (2nd digit) tells the panel which keypad slots are occupied. The
panel can then generate a fault when a keypad supervisory signal is not present. There
are eight available slots for keypads. RF5501-433 keypads are always assigned to slot
1 by default. You will need to assign each keypad to its own slot (1 to 8).
NOTE: The RF5501-433 enrolls as two modules:
1 = keypad section of the RF5501-433
17 = receiver section of the RF5501-433
Enter the following at each keypad installed on the system:
1. Enter Installer Programming by pressing [*][8][Installer's Code]
2. Press [000] for Keypad Programming
3. Press [0] for Partition and Slot Assignment
4. Enter a two digit number to specify the partition and slot assignment.
NOTE: If your system does not have partitions, enter [1] for the first digit.
1st digit
2nd digit
5. Press the [#] key twice to exit programming.
6. After assigning all keypads, perform a supervisory reset by entering [*][8][Installer's
Code][902]. The panel will now supervise all assigned keypads and enrolled
modules on the system.
S
T
A
Enter 0 for Global Keypad, 1-8 for keypad partition
Enter 1 for Partition 1 Keypad
Enter 2 for Partition 2 Keypad
Enter 1 to 8 for Slot Assignment
L
L
A
4
T
I
O
RF5501-433
R
B
RED
COM
N
Y
G
P
P
Z
/
1
2
BLK
DSC
RM-1
NC
NO