Martin Punisher X250 User Manual page 7

Table of Contents

Advertisement

F I T T I N G T H E M A I N S P L U G
The Destroyer/Punisher is delivered from the factory without a plug on the mains
cable. You will have to fit a plug that conforms to your local mains outlet. The
double insulated mains cable contains three wires.
1 Connect the BROWN wire to the LIVE pin.
2 Connect the BLUE wire to the NEUTRAL pin.
3 Connect the YELLOW/GREEN wire to the EARTH pin.
A D J U S T I N G T H E V O L T A G E S E T T I N G
The voltage setting on the Destroyer/Punisher shall match the local power supply.
The factory setting is printed on the serial number label on rear of the unit. If the
setting does not match the local power supply, rewire the unit as follows:
Important! To prevent damage, the RED wire must be connected to an
outside pin as shown.
1 Disconnect the fixture from AC power. Remove the top cover from the unit by
unscrewing the 4 screws that hold it in place.
2 Locate and disconnect the plug with red, yellow, and blue wires at the top-
right corner of the printed circuit board, as seen from the back of the unit.
3 To change to 230 V AC (EU version) or 110 V AC (US version), flip and move
the plug right so that the red wire connects to the pin closest to the edge.
4 To change to 245 V AC (EU version) or 120 V AC (US version), flip and move
the plug left so that the red wire connects to the pin furthest from the edge.
5 Replace the top cover before applying power.
110 V (US)
230 V (EU)
Power setting plug as seen from rear
Setup
120 V (US)
245 V (EU)
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Destroyer x250

Table of Contents