Martin Punisher X250 User Manual page 12

Table of Contents

Advertisement

S
-A
TAND
S T A N D - A L O N E
If the unit does not receive control data, it automatically goes into stand-alone
mode and performs a random sequence triggered by sounds picked up by the
built-in microphone.
S T A N D - A L O N E M A S T E R / S L A V E ( D E S T R O Y E R O N L Y )
If you have two or more Destroyers, this feature allows you to operate all the units
in synchronization. You must assign one, but only one, unit to be master, by setting
DIP-switch 10 OFF. The unit will then be sending DMX signals (via its XLR in
and output connectors) that correspond to what it is doing itself. You can then
connect up to 32 slaves which will all perform exactly the same when set to DMX
address 1.
Important! To prevent damage to the electronic circuitry, one, and only
one, fixture may be set as master (DIP-switch 10 OFF).
1 Disconnect all fixtures from AC power.
2 On the master unit, set DIP-switch 10 OFF.
3 On all slave units, set DIP-switch 1 and 10 ON.
4 Insert a 120Ω female XLR termination plug (P/N
91613018) in the DMX input socket of the master
unit.
5 Connect the DMX output of the master unit to the
input of one of the slaves using a XLR-XLR cable.
Continue the link this way, always connecting
output to input (daisy-chain), until all slaves are
linked together.
6 Finally, insert a 120Ω male XLR termination plug (P/N 91613017) in the free
output socket of the last unit on the link.
7 Apply power first to the master and then to the slave fixtures.
12
O
LONE
Stand-Alone Operation
PERATION
5
Female
Termination Plug
Female XLR
1
2
120
3
P/N 91613018

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Destroyer x250

Table of Contents