Service Time Setting - Nilfisk-ALTO NEPTUNE 1 Service Manual

Hide thumbs Also See for NEPTUNE 1:
Table of Contents

Advertisement

Service time setting.

Fig.G.11: Jumper JP2.
Step:
Switch the machine off with S1 (main switch).
Plug jumper on JP2.
Start the machine in cold water mode with S1 (main switch).
Old service time value is displayed for 5 seconds.
Choose with S2 (temp. Adjustment) the right service time : default value is 200hours.
Switch the machine to hot water mode with S1 (main Switch)
The new service time interval is now stored in the EEProm..
The stored value is displayed at the led's and they are flashing.
Switch the machine off with S1 (main switch).
Remove the jumper from JP2.
Service
LED
Time
Operation
100h
OFF
200h
OFF
300h
OFF
400h
OFF
500h
ON
Fig.G.13: LED lights.
NEPTUNE 1&2_EN_Ver.2.1_45/2014
Adjustment / Test
LED
LED
Fuel
Anti Stone
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
Fig.G.12: S1 & S2 switches.
LED
Service
Boiler Service
OFF
ON
ON
ON
regardless
ON
LED
LED
Flame Sensor
ON
ON
ON
ON
ON/OFF
(EXH-T)
ON
G
102

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neptune 2Neptune 2 special

Table of Contents