BATTERY CHECK/SETTING ON A NEW MACHINE

The machine needs two 12 V lead batteries, connected according to the diagram (44).
The machine can be supplied in one of the following confi gurations:
A)
Batteries already installed and ready to be used
B)
Batteries installed on the machine but without electrolyte
C)
Without batteries
According to machine confi guration, proceed as follows.
A)
Batteries already installed and ready to be used
1.
Open the machine hood (7) and check that the batteries are connected to the dynamotor through the appropriate terminals.
2.
Close the hood (7).
3.
The machine is ready to be used.
If the batteries are discharged, charge them with an external battery charger.
B)
Batteries installed on the machine but without electrolyte
1.
Open the machine hood (7).
2.
Remove all battery caps (45).
WARNING!
Pay attention when using sulphuric acid, as it is corrosive. If it comes in contact with skin or eyes, rinse
thoroughly with water and consult a physician.
Batteries have to be fi lled in a well-ventilated area.
Wear protective gloves.
3.
Fill the battery cells with sulphuric acid for batteries (density from 1.27 to 1.29 kg at 25°C) according to the instructions
shown in the Battery Manual.
The correct quantity of sulphuric acid is shown in the Battery Manual.
4.
Let the batteries rest and fi ll in with sulphuric acid according to the instructions shown in the Battery Manual.
5.
Charge the batteries with an external battery charger.
C)
Without batteries
1.
Buy appropriate batteries (see the Technical Data paragraph and the diagram (44)).
For the battery choice and installation, apply to qualifi ed battery Retailers.
2.
Install the batteries.
3.
Charge the batteries with an external battery charger.

BEFORE MACHINE START-UP

CAUTION!
Make sure that there are no open doors/hoods and that the machine is in normal operating conditions.
Make sure that the hopper (17) is properly closed.
If the machine has not been used after being transported, check that all the blocks used for the transportation
have been removed.
1.
If necessary, open the hood (7), unscrew the cap (61), and refuel; then close the hood (7).
CAUTION!
Do not fi ll the fuel tank to the top. Do not fi ll the fuel tank to the top, but leave at least 25 mm from the fi ller neck
to allow the fuel to expand.
2.
Perform the maintenance procedures according to the Scheduled Maintenance Table (see the relevant paragraph).