Glass & Trim Fitting; Door Trim; Fire Door Glass - Aarrow Becton MK 2 Operating & Installation Manual

Range of gas stoves
Table of Contents

Advertisement

SERVICING

DOOR TRIM

Becton fire doors are fitted with a brushed steel
finish trim as standard. This, clips on to the small
lugs at the top and bottom of the aperture in the cast
iron fire door, as a "spring fit". When fitted, the trim
locks the glass retaining clips in position. (Fig 10)
The fire door should be removed so that the above
operations can be carried out on a workbench or
similar. Remove the door by GENTLY tapping the
door upwards; this will lift off of its hinges.
Trim Fit. Fig. 10

FIRE DOOR GLASS

If necessary the glass can be removed as follows
GLASS
Step 1 Remove the brushed steel finish trim by
GL ASS CLIP
pressing on the curved edge at the top until the trim
GASK ET
can be disengaged from the lugs.
FIRE DOOR
Step 2 Slide the two glass retainer clips on one side
only, inwards, towards the centre of the door as far
as they will go.
Step 3 Pull this side of the glass away from the door
casting, easing the tags on the glass retaining clips
past the edge of the aperture in the door casting.
Step 4 Remove the glass completely. Store
glass-retaining clips and white gasket (if sound)
safely for re-use.
Step 5 Follow this procedure in reverse to fit
replacement door glass or gasket.
Glass Fit. Fig 11
18