Page 1
Operating & Installation Manual The Becton MK 3 Range of Gas Stoves (Becton 7 MK 3 Gas Stove) PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Aarrow Fires Ltd The Fireworks Bridport Dorset, DT6 3BE Great Britain FOR USE IN COUNTRIES GB &...
Page 2
This booklet has copyright & may not be copied in whole or part or used for any purpose other than that for which it is supplied without express written consent from Aarrow Fires Ltd. Becton Bunny & Becton 7 mk3 Gas stoves...
Combustible Shelf Clearances Hearth Requirements Connecting The Gas Supply Pressure Test Sequence Fire Testing Installation Check List Becton Bunny & Becton 7 mk3 Gas stoves Page SERVICING Details of Pilot Assembly Door Trim Fire Door Glass & Seal Burner Assembly...
• Always grip with the palms of your hands. Do not use fingertips for support. • Always keep the stove as close to the body as possible. This will minimise the cantilever action. • Use gloves to provide additional grip. Becton Bunny & Becton 7 mk3 Gas stoves...
First position the tall edge into the radius at the front of the fire.(See Fig.3b below) Fig. 3b Fitting the R/H side lining Becton Bunny & Becton 7 mk3 Gas stoves OPERATING INSTRUCTIONS 3. Then rotate the rear edge until the top faces match up the angle faces at the rear of the fire.
(Fig 4b) Fig 4b Step 3 Becton 7 only. Locate 2 off end coals each side of the base matrix. (See underside of coals for hand identification) (Fig 4c). Fig 4c Becton Bunny & Becton 7 mk3 Gas stoves...
Step 1b. Keep the control knob pressed in and turn anti-clockwise to the pilot position. (Fig 5b) Fig 5b Becton Bunny & Becton 7 mk3 Gas stoves OPERATING INSTRUCTIONS Step 1c. Keep the control knob pressed in for a further 15 seconds and then release. The pilot will remain alight.
Page 10
In this situation no more attempts at operating the appliance should take place and your qualified gas engineer should be contacted to investigate and rectify the problem. Becton Bunny & Becton 7 mk3 Gas stoves...
Building Regulations. The minimum effective height of the Becton Bunny & Becton 7 mk3 Gas stoves chimney must be at least 3 metres and when warm the flue draught should be between 0.05 and 6mb (0.5mm to 6mm water gauge).
Page 12
(Ref. Fig. 6c). It is recommended that a smoke test is performed inside the fire to ensure that adequate flue draw is evident. Fig 7a Becton Bunny & Becton 7 mk3 Gas stoves...
INSTALLATION non- combustible closure plate, incorporating access for cleaning debris. Fig. 7b. Fig. 7c Becton Bunny & Becton 7 mk3 Gas stoves non- combustible closure plate, incorporating access for cleaning debris. Fig. 7d. FIRE LOCATION The appliance must not be installed in a room or space, which contains a bath or shower.
1. Graph 1.Combustible Shelf Clearances The recommended minimum height from the extreme top surface of the fire to the underside of a non combustible shelf is 100mm. Becton Bunny & Becton 7 mk3 Gas stoves...
This is perfectly normal and is due to the paint curing, it will disappear after the first few hours. Once the spillage test is complete open windows and doors to ventilate the area. Becton Bunny & Becton 7 mk3 Gas stoves...
This in turn will reduce condensation in the chimney and any associated flue problems. The pilot can be viewed through the L/H & centre front slots in the base matrix. Fig. 10 Becton Bunny & Becton 7 mk3 Gas stoves...
The tracery can now be removed. (See Fig. 11c below) Fig. 11c Untightening the single tab Becton Bunny & Becton 7 mk3 Gas stoves Step 3 The trim will now lift off the remaining 2 tabs. See Fig. 11d.
(See “Safety Notices” under ‘Coal set’ on page 4). Step 5 Replace the coal set. See assembly procedure on page Step 6 Replace glass/gasket assembly and glass frame. Step 7 Close fire door. Becton Bunny & Becton 7 mk3 Gas stoves SERVICING...
Step 11 Replace fire box linings. Step 12 Replace coal set. Becton Bunny & Becton 7 mk3 Gas stoves Step 13 Replace glass/gasket and glass frame and close the fire door. Step 14 Carry out spillage test as per instructions on page 16.
Check all pipe connections check main valve magnet Investigate flue systems Becton Bunny & Becton 7 mk3 Gas stoves Does the main burner light? Fire satisfactory Is the main injector blocked? Clean and replace as necessary...
Paint- Matching aerosol paint to tone in any connecting flues, pipes or surrounding metalwork Tracery or Trim - Note: When fitted one replaces the other. Becton Bunny & Becton 7 mk3 Gas stoves Add on Canopies Bunny - Low available only Size: 400mm wide x 345mm deep.
Annual service on page 30 should be completed by your service engineer. Becton Bunny & Becton 7 mk3 Gas stoves All Guarantee periods commence on the date of purchase and are non-transferable.
Should you have any questions about your Becton Gas Stove that is not covered in this manual please con- tact your Aarrow retailer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits as they will complete the service record chart. Becton Bunny & Becton 7 mk3 Gas stoves...
Lifetime Guarantee For your peace of mind Aarrow Fires gives a Lifetime Guarantee against manufacturing defects of the main body* of its Becton range of fires. Additionally, all other parts are covered by a one year no quibble replacement guarantee. This guarantee covers replacement of the item only and does not extend to any other costs, including labour, incurred in its replace- ment.
HOTPLATE OPERATING INSTRUCTIONS GAS COCK FEET & FIXINGS Please ensure the enclosed registration card is completed and returned to Aarrow Fires and the following information completed for your own information. Date of Purchase... Name and address of supplier... * Please ensure installer completes INSTALLATION CHECK LIST details on page 17 of this manual.
Need help?
Do you have a question about the Becton 7 mk3 and is the answer not in the manual?
Questions and answers