Aarrow Sherborne Sherborne  Wood & Multifuel Stoves Operating & Installation Manual

Aarrow Sherborne Sherborne Wood & Multifuel Stoves Operating & Installation Manual

Wood & multifuel stoves

Advertisement

Operating & Installation Manual
Sherborne
Wood & Multifuel Stoves
Sherborne Medium Multifuel Stove
PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
Arada Ltd
The Fireworks
Bridport
Dorset, DT6 3BE
Great Britain
Rev 2
Tel. (44) 01308 427234
Nov 2006
Fax. (44) 01308 423441
AFS1237
www.aarrowfires.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sherborne Sherborne Wood & Multifuel Stoves and is the answer not in the manual?

Questions and answers

Summary of Contents for Aarrow Sherborne Sherborne Wood & Multifuel Stoves

  • Page 1 Operating & Installation Manual Sherborne Wood & Multifuel Stoves Sherborne Medium Multifuel Stove PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Arada Ltd The Fireworks Bridport Dorset, DT6 3BE Great Britain Rev 2 Tel. (44) 01308 427234 Nov 2006 Fax. (44) 01308 423441 AFS1237 www.aarrowfires.com...
  • Page 2 Congratulations on your choice of an Aarrow Stove. More than 20 years experience has been put into the development of our Sherborne, range to ensure ultimate performance and years of trouble free Every detail on the stoves has been carefully engineered and designed which is why we are so confident in the reliability of our product that we offer a Lifetime Guarantee.
  • Page 3: Table Of Contents

    INTRODUCTION Safety Notices The Principle of the Fire Check List Technical Data OPERATING INSTRUCTIONS Firebox Linings and Throat Plate Removal Multifuel Grate Wood Stove - Wood Tray Air inlet Controls/Airwash System Multi-Purpose Operating Tool Fire Door Glass Door Adjustment Fuel Retainer Bars Fitting the Feet Fuel Types Lighting The Fire...
  • Page 4 TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www.solidfuel.co.uk THE USE OF SPARE PARTS OTHER THAN THOSE SUPPLIED BY AARROW FIRES LTD WILL INVALIDATE THE APPLIANCE GUARANTEE. Sherborne Wood & Multifuel Stoves...
  • Page 5: Introduction

    Aarrow Fires are also fitted with an "air wash" so called because it provides a curtain of high speed preheated air behind the glass to help keep it clean and to provide secondary air/over draught.
  • Page 6: Check List

    CHECK LIST Part Description & Visual Aid (not to scale) 1. Grate bars 2. Fuel retainers 3. Throat plate 4. Flue spigot 5. Hotplate 6. Ashpan 7. Operating tool 8. Rear liner 9. Side liners 10. Woodburning tray 11. Multifuel riddling kit 12.
  • Page 7: Technical Data

    TECHNICAL DATA Room Min/Max Room Heater Only Output (kW) Room Heater with Domestic Hot Water with add in boiler type Max Output to Room (kW) Max Output to Water (kW) Height (mm) Width (mm) Depth (mm) Height to Centre of Rear Flue Depth from Back to Centre of Flue (mm) Flue Diameter...
  • Page 8: Operating Instructions

    OPERATING INSTRUCTIONS FIREBOX LININGS & THROAT PLATE The Sherborne range of Wood and Multifuel stoves firebox have reflective liners to the sides and rear and a specially shaped throat plate which sits on the liners. If these are not in place please refer to page 17 to install these.
  • Page 9: Multi-Purpose Operating Tool

    Fig. 4b Lifting cover from body of stove Fig. 4c Unscrewing MULTI - PURPOSE OPERATING TOOL Your Aarrow fire comes with a multi-purpose tool, which is used for riddling, setting the multifuel grate position. Use the operating tool for setting the grate in the coal burning position or the wood burning position.
  • Page 10: Door Adjustment

    OPERATING INSTRUCTIONS DOOR ADJUSTMENT Once the appliance has been under fire for a period of time the fire door may appear to have moved out of alignment with relation to the door aperture. This is quite normal and due to the settling of the casing. The fire door can be re-aligned by the user as follows: •When the appliance is cold, open the fire door so...
  • Page 11: Fuel Types

    FUEL TYPES Wood- Any type of wood is suitable provided it is well seasoned and has a moisture content below 20%. This usually implies that the timber has been suitably stored to allow moisture to evaporate for at least nine months in the case of soft woods, and at least eighteen months in the case of hard wood.
  • Page 12: Burning Wood

    OPERATING INSTRUCTIONS ENSURE THAT YOU HAVE READ & UNDERSTOOD THESE INSTRUCTIONS BEFORE LIGHTING THE FIRE. ALWAYS WEAR SUITABLE PROTECTIVE FIRE GLOVES WHEN REFUELLING YOUR STOVE. SOLID FUEL BURNING •Set the grate to ‘coal’ position. •Ensure that the ash pan is in position and the fire doors are closed.
  • Page 13: Over Firing

    • Check for flue or chimney blockage, and clean if required. Seek expert advice from your HETAS registered installer. Do not attempt to re-light the fire until the cause of the fume emission has been identified and corrected. ASH REMOVAL - Wood burner only Ash will drop through the holes and to the slides of the specially designed wood tray.
  • Page 14: Chimney Sweeping

    SERVICING Remove the firebricks lining and throat plate, inspect all gasketing on doors, glass etc., and re-order any items that may need replacing, from your Aarrow dealer. With a wire brush clean inside the appliance paying particular attention to the small inlet holes of the air wash on the inside, above the fire door and to the door.
  • Page 15: Accessories

    ACCESSORIES WOOD BURNING TRAYS To turn your multifuel stove into a dedicated woodburner. As shown in Fig. 10a below Fig. 10a MULTIFUEL UPGRADE KIT Available for the wood burning range to enable you to burn solid fuel in your Sherborne woodburning stove. (See Fig.
  • Page 16: Installation

    INSTALLATION GENERAL PRECAUTIONS Note - All installations must conform to the appropriate building regulations. The Building Regulations for England and Wales 2000 ref Approved Document J 2002 edition (issued by the DTLR). The Building Standards (Scotland) (Consolidation) Regulations. Detailed recommendations for installation of appliances, chimneys and flues are outlined in the current issue of the following British Standards:- BS6461, BS8303 and BS4543.
  • Page 17: Firebox Liner Panels

    FIREBOX LINER PANELS The Sherborne Wood and Multifuel stoves use reflective liners to the sides and back. The throat plate sits on top of the side and rear panels. These should come fitted to your fire, if however they are not proceed as follows to fit them.
  • Page 18: Assembling The Multifuel Grate

    INSTALLATION MULTIFUEL GRATE GRATE The grates in the Sherborne Multifuel units comprise a series of reciprocating cast iron bars seated on a pivoted "comb". All bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked "H" sit- ting on the high sections of the comb, and the ends marked "L"...
  • Page 19: Interchangeable Canopies

    INSTALLATION INTERCHANGEABLE CANOPIES The canopy versions for the Sherborne range are slab top stoves to which a low or high canopy can be fitted after installation and are interchangeable. These are fitted as follows: •To fit the interchangeable canopy (Fig 10c): •Remove the front clamps.
  • Page 20: Fitting The Flue Outlet And Hot Plate

    INSTALLATION FITTING THE FLUE OUTLET AND HOT PLATE The flue outlet spigot is found inside the appliance. The hot plate (blanking plate) is supplied fitted to the top opening and is removed by turning clockwise (as is the flue outlet). Smear a very thin layer of fire cement on the faces of the flue outlet and the blanking plate.
  • Page 21: For All Appliances

    Due to the gradual introduction of European Chimney Standards chimneys will be specified according to their performance designation as defined in BS EN 1443 that covers the General Requirements for chimneys. The minimum performance designation required for use with solid fuel burning stoves is T450 N2 S D3.
  • Page 22 INSTALLATION Sherborne Wood & Multifuel Stoves...
  • Page 23 INSTALLATION YPICAL ETAL NSULATED HIMNEY YSTEM O BE INSTALLED TO THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE BS7566 P WITH BUILDING REGULATIONS AND IEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES A is minimum clearance for non-insulated flue = 1.5 x D to a non-combustible surface/material 3 x D to combustible surface/material Sherborne Wood &...
  • Page 24: Add In Boilers/Water Connections

    INSTALLATION ADD IN BOILERS Sherborne Wood and Multifuel stoves offer the option of a slab boiler, which occupies the position of the rear firebox liner panels. Fitting: •Remove the fuel retainers, rear firebox liner panels and throat plate. •Knock out the blanking discs in the back plate corresponding to the terminals on the boiler.
  • Page 25: Final Check

    Primary flow and return pipes should be 28mm diameter. The cylinder should be installed at a higher level than the appliance, and as close to it as possible (the higher the cylinder the faster the circulation). The flow and return pipes should not be longer than 20ft each.
  • Page 26: Final Installation Check List

    INSTALLATION Hearths, Fireplaces, Flues and chimneys This checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory, and to show what you have done to comply with the requirements of The Building Regulations 2000 Approved Document J 2002. 1. Building address, where work has been carried out... 2.
  • Page 27: Parts List

    Visual Aid Part Description (not to scale) 1. Fuel Retainers 2. Throat Plate 3. Grate Bar Set 4. Hot Plate 5. Operating Tool 6. Ashpan 7. Flue Spigot Sherborne Wood & Multifuel Stoves Sherborne Sherborne Sherborne Small Small Medium Wood Multifuel Wood AFS1192 AFS1192...
  • Page 28 PARTS LIST Visual Aid Part Description (not to scale) 8. Liner Set 9. Side Liner 10. Back Liner 11. Glass Replacement Kit Complete with Gasket 12. Glass Clips 13. Hinge kit Comprises 2 Hinges & 4 Fixings Per Set. 14. Airwash (Curved) 15.
  • Page 29 Visual Aid Part Description (not to scale) 16. Fire Door Rope Kit Complete with Door Rope Glue. 17. Main Door Assembly Complete with Handle,Glass, Gaskets,Clips and Seal. 18. Replacement Instruction Manual 19. Fire Door Locking Assembly 20. Wood Burning Tray 21.
  • Page 30: Lifetime Guarantee

    Final Installation Check List on p26 has been completed and signed by a suitably qualified engineer. USE OF SPARE PARTS OTHER THAN THOSE SUPPLIED BY AARROW FIRES WILL APPLIANCE WARRANTY. All Guarantee periods commence on the date of purchase and are non-transferable.
  • Page 31: Service Record

    SERVICE RECORD Company Work Carried Out Signature Date of Visit Should you have any questions about your Sherborne Wood or Multifuel Stove that is not covered in this manual please contact your Aarrow retailer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits as they will complete the service record chart.
  • Page 32: Final Factory Check List

    FINAL FACTORY CHECK LIST Model... Serial No... QUALITY FINISH PARTS FLUE OUTLET HOT PLATE FUEL RETAINERS X2 GRATE BARS / WOOD TRAY FIREBOX LININGS THROAT PLATE AIR WASH DOOR CATCH ASH PAN OPERATING TOOL OPERATING INSTRUCTIONS Please ensure the enclosed registration card is completed and returned to Arada Ltd and the following information completed for your own information.

Table of Contents