User Parameter Pass Through

Parameter # F1h 71h
Enable this to send user-defined parameter bar codes (see
normal decode data in decode data packets for SSI and SNAPI hosts (see
User-Defined Parameter Bar Code Format
Code 128 bar codes with:
<FNC3><L><data>
or
<FNC3><B><12 bytes of data>
Decode Data Format
<0xf3><L><data>
or
<0xf3><B><12 bytes of data>
Note that the
type only works with 12 bytes of data.
B
A normal decode beep sounds upon a successful decode of a user-defined parameter bar code.
Enable User Parameter Pass Through
(01h)
User-Defined Parameter Bar Code
Decode Data
*Disable User Parameter Pass Through
(00h)
Format) as
Format).