4 - 32 PL3307 Decoder Integration Guide
Diagnostic Testing and Reporting
Use the ATT_DIAGNOSTIC_REPORT command to retrieve system information. Refer to PARAM_REQUEST
in the SSI Programmers Guide for details.
The following are reported to the host for each test case. The result consists of 2 bytes: an 8 bit test number
and an 8 bit test result.
Diagnostic Report Format
Table 4-2
Byte Offset
Data byte 0
Data byte 2
Data byte 4
Data byte 6
Data byte 8
Data byte 10
Data byte 12
Test Result Table
Table 4-3
Test Result
0
1
2
3
4
5
6
7
8
Test Name
2
I
C interface
Laser current
Laser MDIop current
Operating temperature
Laser current stored
Laser MDIop current stored
Operating temperature stored
Description
Pass
Fail
Not tested
NA
High
Low
Warning
Critical
Fatal
Results
Pass / Fail
Pass / High / Low
Pass / High / Low
Pass / Warning / Critical
Pass / High / Low
Pass / High / Low
Pass / Warning / Critical