5. The machine must be connected to the water line
with cold water or up to 60° C warm water (see
page 2).
The hose cross section must be at least 3/4" =
16 mm (free passage). Filter 1 must always be
clean.
Please make sure that the filter is clean before
using your high pressure cleaner.
CAUTION !
When running your high pressure cleaner with hot water of 60° C rai-
sed temperatures occur.
Do not touch the pump without safety gloves!

External suction

Undercarriage
3/4" (Order no.: 46.004) to the connection hose.
Make sure that the water is clean. Use the Kränzle suction hose with suction filter.
(Order no. 15.038 3)
Maximum suction height 2.5 m, maximum water temperature for direct suc-
tion: 60°C
(see technical data on page 2)
Preparation for use
If water is to be suk-
ked from an external
container for the high
pressure cleaner, the
connection hose bet-
ween the high pressu-
re pump and the water
tank must be screwed
off and the suction
hose must be connec-
ted via a double nipple
1
Undercarriage