golmar T631/PLUS Instruction Manual page 47

Audio and video door entry system
Table of Contents

Advertisement

150
A
uxiliary devices activation.
To activate auxiliary devices the use of a SAR-12/24 relay unit will be required. If this device is shared
for all monitors, link their A1 terminal and use just one relay unit. In case that each monitor has its
own application use a SAR-12/24 relay unit for each monitor and don't link the A1 monitor
terminals.
To activate this function, press
handset position.
Usual applications are the activation of stairs light, second lock release, ...
CN4
+
To distributor/
door panel.
( )
The neutral supply from the stairs light will be wired through the relay contacts SAR-12/24, the maximum current for stairs
*
light will be 1.8A.
The use of a TF-104 transformer will be necessary to activate a second lock release.
CN4
+
To distributor/
door panel.
monitor push button at any moment with no dependence of the
Platea Plus /
Tekna Plus
_
V
V
A
D
A1
Malla
in
out
Platea Plus /
Tekna Plus
_
V
V
A
D
A1
Malla
in
out
OPTIONAL CONNECTIONS
NC
NA
C
SAR-12/24
IN
IN
NC
NA
C
SAR-12/24
IN
IN
To stairs light
push button
P
( )
220 Vac/
*
1.8A max.
N
TF-104
PRI SEC
~
~
~
~
Main
Lock release
Vac.

Advertisement