Mode 2 Bidirectional Timing - National Instruments PC-DIO-96 User Manual

Digital i/o board for the ibm pc/xt/at
Table of Contents

Advertisement

Chapter 2

Mode 2 Bidirectional Timing

The following figure illustrates the timing specifications for bidirectional transfers in mode 2.
WR*
OBF*
INTR
ACK*
STB*
IBF
RD*
DATA
Name
Description
T1
WR* = 1 to OBF* = 0
T2
Data before STB* = 1
T3
STB* pulse width
T4
STB* = 0 to IBF = 1
T5
Data after STB* = 1
T6
ACK* = 0 to OBF = 1
T7
ACK* pulse width
T8
ACK* = 0 to output
T9
ACK* = 1 to output float
T10
RD* = 1 to IBF = 0
All timing values are in nanoseconds.
© National Instruments Corporation
T1
T6
T7
T3
T4
T2
T5
T8
Minimum
Maximum
150
20
100
150
50
150
100
150
20
250
150
2-17