Operating Instructions; Description Of Unit; The Most Important Points In Brief; Operation - STIEBEL ELTRON sH 10 sl Operating And Installation Instructions

Clesed (pressurized) water storage heater
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
1. Operating Instructions
1.1 Description of Unit
• The closed (pressurized) water storage he-
ater keeps the water content permanently
ready at the pre-selected temperature.
• Only tap fittings in conjunction with the
KV 307 or KV 40 safety group may be used.
1.2 The most important points
in brief
• Set the desired hot water temperature
using the temperature selector (1)
• An illuminated display (2) indicates that
the unit is heating up.

1.3 Operation

Temperature setting
°C = cold. At this setting the unit, but not
the fitting or water pipe, is protected
from frost
Eco = At this setting the unit is protected
from frost, although this does not
protect the fitting or the water pipe.
82 = max. temperature setting.
Note:
On request, the engineer can set a tempera-
ture limit on the unit (see .8 "First Use") so
that the temperature is fully adjustable up to
this limit.
Heat up time:
If the entire water content is used, the heat up
time is as indicated in the graph.
[min]
40
35
30
25
20
15
10
5
0
35 °C
55 °C E 65 °C
Example SH 10 SL | SH 10 SLi:
Temperature setting:
65 °C
Heat up time:
approx. 18 minutes
10
for the user and engineer
Mixing water quantity:
Using the temperature, you set a mixed water
quantity for e.g. 40 °C.
[ l ]
45
40
35
30
25
20
15
10
5
0
40 °C
55 °C E 65 °C
1
Example SH 10 SL | SH 10 SLi:
Temperature setting:
Cold water feed:
Mixed water quantity:
2
1.4 Important Note
• The water storage heater is under
mains water pressure.
• During heating up, water will drip out of
the safety valve.
If water continues to drip out of the safety
valve after heating up has been completed,
the device must be switched off and depres-
surized, and a qualified installer called.
• The blow-out line of the safety valve must
not be closed.
• With temperature settings over 45 °C, wa-
ter at a high temperature may start flowing
immediately.
• If it is intended that children or people
with restricted physical, sensory or mental
capabilities are to operate the appliance,
they must only be permitted to do so after
appropriate instruction has been provided by
the person responsible for their safety.
Children should be supervised to ensure that
SH 15 SL
they do not play with the device.
SH 15 SLi
Risk of scalding!
2 kW
To avoid risk of accidental resetting of the
S H 10 SL
protective temperature restrictor in the event
SH 10 SLi
2 kW
of a fault, the unit must not be connected via
3,3 kW
a timer switch.
SH 15 SL
SH 15 SLi
Limescale can block the outlet and cause pres-
sure to build up in the heater.
Signs of limescale are boiling sounds and re-
duced water flow. In such a case, the unit and
82 °C
fitting must be descaled by an engineer.
The thermostat knob may only be removed by
an engineer.
All information in these Operating and In-
stallation Instructions must be observed. The
instructions contain important information for
safety, operation and maintenance of the unit.
1.5 Care and Maintenance
To clean the unit, simply wipe with a damp
cloth. Do not use abrasive or aggressive clea-
ning agents.
SH 15 SL
SH 15 SLi
1.6 What to do if....
S H 10 SL
SH 10 SLi
... there is no hot water:
Check the thermostat, plug and fuse.
...there is a boiling sound from the unit:
Have the unit and fitting descaled by an en-
gineer.
... see also 3. „Defect rectification for the user
and engineer".
82 °C
If an engineer is called out for a problem, to
help him resolve this problem quickly and effi-
65 °C
15 °C
ciently, please give him the information on the
approx. 20 l
unit rating plate, as shown below (8):
Nr.: ...... - .... - ......
Typ: SN .. SL
1.7 Sonderzubehör
Stiebel Eltron Bestell-Nummern:
• safety group
– KV 307 (0.7 MPa) 00 07 57
– KV 40 (0.6 MPa) 00 08 28
• installation kit "Permanent electrical con-
nection"
– installation kit
Maintenance work should only be
performed by an engineer.
..............
22 32 19