Connecting Stations And Additional Equipment - Samsung OfficeServ 7200-S Installation Manual

Hide thumbs Also See for OfficeServ 7200-S:
Table of Contents

Advertisement

OfficeServ 7200-S
TECHNICAL MANUAL
PART 7. CONNECTING STATIONS AND ADDITIONAL
EQUIPMENT
This section describes how to connect various stations and additional equipment, such as
analog/digital phones, door phones and door locks, to the OfficeServ 7200-S system.
7.1 CONNECTING STATIONS
7.1.1 Safety Precautions
To reduce the risk of personal injury, follow these precautions before connecting telephone
circuits:
• Never install telephone wiring during a lightning storm.
• Never install telephone jacks in a wet location unless the jack is specifically designed for
wet locations.
• Do not connect stations in a humid area.
• Never touch non-insulated telephone wires or terminals unless the telephone line has
been disconnected at the network interface.
• Connect stations using #24 AWG or #26 AWG cables.
The maximum distance between stations and the OfficeServ 7200-S are as follows:
Digital phone
Analog phone
Door phone
AOM
Table 7.1 Distance Between Stations and the System
Station
7.1
Distance
Maximum 400m / 1312ft (for AWG #24)
Maximum 1km / 3280ft (for AWG #24)
Maximum 400m / 1312ft (for AWG #24)
Maximum 400m / 1312ft (for AWG #24)