around the inlet pipe to prevent the
entrapment of swimmers.

Electrical Connections

Connect the pump to a separate electrical
circuit with a dedicated circuit breaker.
Refer to the electrical specifications in
wiring chart for recommended fuse and
wire size.
Install and maintain wiring for this pump in
accordance with the National Electrical
code and all applicable local electrical
codes.
The motor must be grounded by
connecting a copper conductor to the
grounding screw provided within the
wiring compartment.
The voltage of power supply must match
the voltage of the pump. The WLS75,
WLS100 and WLS150 have dual voltage
motors preset at the factory to 230 volts.
The motors can be converted to 115 volts
by turning the voltage selector to the
desired voltage (See Figure 5). Use a
needle nose pliers to pull the selector out
approximately 1/4", rotate and then reinsert
in correct position. NOTE: The WLS200
cannot be converted; the motor is
230 volts only.
CONNECTING WIRES
Terminal cover must be in place for safe
operation. Ground in accordance with local
and national electrical codes. Keep fingers
and objects away from openings and rotating
Pressure (psi)
Head
(ft)
15
20
5
3100
2700
10
2900
2550
15
2750
2400
20
2600
2200
25
2450
2050
WLS75 - GPH
Pressure (psi)
Head
(ft)
15
20
5
4350
3950
10
4200
3700
15
3950
3450
20
3700
3250
25
3500
3050
WLS150 - GPH
Figure 5 - Voltage Selector
Figure 6 - Connecting Wire
Head
25
30
(ft)
2350
1950
5
2200
1700
10
2000
1400
15
1750
1000
20
1450
500
25
WLS100 - GPH
Head
25
30
(ft)
3400
2950
5
3200
2750
10
3000
2500
15
2800
2150
20
2550
1700
25
WLS200 - GPH
GROUND
SCREW
TERMINAL
BOARD (L2)
Pressure (psi)
15
20
25
30
3650
3200
2800
2450
3450
3000
2650
2200
3250
2850
2450
1950
3050
2650
2300
1600
2850
2500
2050
1150
Pressure (psi)
15
20
25
30
--
5300
4800
4200
--
5100
4500
3950
5300
4850
4250
3750
5150
4550
4000
3450
4850
4300
3750
3100
3
WLS Series
parts. Disconnect power sources before
touching internal parts. See Figure 6 for
appropriate wiring locations.

Operation

NEVER run the
pump
dry. Running pump
without water may cause seal damage.
Fill the pump with water before
starting.
PRIMING THE PUMP
After pump installation is complete, the
pump must be primed. Remove the pipe
plug in the discharge piping and fill the
pump and suction pipe with clean water.
Turn power to pump on. If the pump
does not pump water in 10 minutes, turn
off the pump and refill with clean water.
If the pump does not operate after
repeated attempts, check the following:
1. Vertical distance of pump to water
level must not be over 25 feet.
2. Suction piping must be air tight.
3. Be sure valve(s) are open if used in
discharge or suction piping.
NEVER run the
pump
with a closed or
clogged discharge. The water inside the
pump could boil and damage the pump.

Maintenance

Maintain adequate ventilation for the
pump motor. The motor bearings are
permanently lubricated at the factory.
Additional lubrication is not required.
DRAINING FOR WINTER
Always protect pump and piping against
freezing temperatures. If there is any
danger of freezing, drain the system. To
drain the system:
1. Remove the pipe plug from the
discharge tee.
2. Remove the 1/4" plug from the lower
front face of the pump.
3. Drain all piping below the frost line.