Page 1
CRX9 即 熱 式 電 熱 水 器 即 热 式 电 热 水 器 Instantaneous Water Heater 在使用之前請詳細閱讀 「使用說明書」及「保用條例」 , 並妥為保存。 在使用之前請詳細閱讀「使用說明書」及「保用條例」 , 並妥為保存。 Please read these instructions and warranty information carefully before use and keep them handy for future reference.
CRX 9 1. Overview Layout of appliance Pos. Description Pos. Description Brass connection set with back flow Electronic board prevention in hot water outlet Flow sensor Heating element Cable seal Display panel Safety thermal cut out not shown: set of small spareparts When ordering spare parts, please always specify the appliance model, nominal rating and serial number!
Page 3
CRX 9 2. Table of contents 1. Overview ..................................2 2. Table of contents ................................3 3. Technical specifications ..............................3 4. Operating instructions ...............................4–6 5. Customer service ................................7 6. Installation ................................8–13 Warranty Terms and Conditions ............................38 Customer Service Center ..............................39 中文使用說明書從第...
Page 4
CRX 9 4. Operation instructions G E FA H R Safety instructions for closed-outlet water heaters: • Installation, initial operation and maintenance of this appliance must only be conducted by an authorised profes- sional, who will then be responsible for adherence to applicable standards and installation regulations. We assume no liability for any damages caused by failure to observe these instructions.
Page 5
CRX 9 4. Operation instructions G E FA H R If the heater supplies two outlets, the water from the unit will be shared between the outlets. You should therefore only use one outlet at a time in order to obtain a sufficient flow. At high feed temperatures, the power is automatically switched off by the electronics in order to avoid producing exces- sively hot water.
Page 6
CRX 9 4. Operation instructions G E FA H R Cleaning the fine filter (flush-mounted) The fine filter is located in the water connection (10) and should be examined by an expert and cleaned if necessary not only when operation of the appliance deteriorates, but also in conjunction with regular servicing.
If you experience a malfunction, please try to rectify the fault your self first with the help of this table. If a fault in your appliance cannot be rectified with the aid of this table, please contact German Pool who will either assist you directly or put you in touch with a customer service contract partner in your area.
CRX 9 6. Installation If you install the instantaneous water heater CRX 9 instead of a conventional instantaneous water heater, there is gener- ally no need to drill holes for the wall holder. In this case, you only need to screw in the double nipples as described in 2. and to secure the wall bracket.
Page 9
CRX 9 6. Installation Installing the wall bracket (surface-mounted): 1. Thoroughly rinse the water supply pipes before installation to remove soil- ing from the pipes. 2. Screw the 1/2“ screw in nipple and the 1/2“ seal into the 1/2“ union nuts of the hot-water connector.
Page 10
CRX 9 6. Installation Installation instructions for the authorized technician • The statutory regulations of the respective country, as well as those of the local electricity and water supply companies. • The specifications on the rating plate and the technical specifications. Installation site G E FA H R • The installation site must be free from frost at all times. • The appliance complies with protection type IP25 and may be installed in zone 1 acc. IEC • In order to avoid thermal losses, the distance between the heater and the tapping point should be as small as possible (<...
Page 11
CRX 9 6. Installation Installing the appliance: 1. Rinse water supply pipes thoroughly and turn off for instal- lation. 2. Remove the front cover by unscrewing the locking screw behind the small lid. 3. Locate and break out the required holes and cable inlets. Mark the drilling holes with the appliance and drill them with a 6 mm bit.
Page 12
CRX 9 6. Installation Closed flush-mounted installation 9. Turn on the water supply and slowly open the shutoff valve (10 a) in the cold-water connection (position I) if necessary. Check all connections for leaks. 10. Next, open and close the hot water tap several times until no more air 10 a emerges from the line and all air has been eliminated from the heater.
5. Explain the user how the instantaneous water heater works and hand over the operating instructions. 6. Fill in the guarantee registration card and send it to the German Pool Central Customer Service or use the online registration on our website...
Page 22
CRX 9 6. 安裝 適用于經授權技術人士的安裝說明 · 各國家/地區的法律規定以及當地的電力和供水公司的規定。 · 標稱銘牌上的規格和技術規格。 安裝地點 G E FA H R · 安裝地點必須一律為無霜環境。 · 設備符合保護類型 IP25 並且可根據 IEC 安裝在區域 1。 · 要避免熱量流失,熱水器和分接點的距離應盡可能小 (< 2 m)。 · 流動壓力大於等於 3 bar 時可以保證最佳性能,請避免壓力超過 6 bar。 · 管式加熱器型號的水管材料:冷水:鋼或銅,熱水:銅。 G E FA H R 重要注意事項!...
Page 34
CRX 9 6. 安装 适用于经授权技术人员的安装说明 · 各国家/地区的法律规定以及当地的电力和供水公司的规定。 · 标称铭牌上的规格和技术规格。 安装地点 G E FA H R · 安装地点必须一律为无霜环境。 · 设备符合保护类型 IP25 并且可根据 IEC 安装在区域 1 · 要避免热量流失,热水器和分接点的距离应尽可能小 (于 2 m)。 · 流动压力大于等于 3 bar 时可以保证最佳性能,请避免压力超过 0.6 MPa (6 bar)。 · 管式加热器型号的水管材料: 冷水: 钢或铜,热水: 铜 G E FA H R 重要注意事项!...
取檢查或測試費用。 取檢查或測試費用。 Service Centre are subject to testing and handling charges. 5. 總代理有權選擇維修或更換配件或其 5. 總代理有權選擇維修或更換配件或其 5. German Pool will, in its discretion, repair or 損壞部份。 損壞部份。 replace any defective part. 6. 產品一經被轉讓,其保用即被視作無 6. 產品一旦被轉讓,其保用即被視作無 6. This warranty will be void if there is any transfer of ownership from the original 效。...
Page 39
Customer Service Centre 客戶服務部 客戶服務部 Hong Kong 香港 香港 German Pool (Hong Kong) Limited 德國寶(香港)有限公司 德國寶(香港)有限公司 +852 2333 6249 +852 2333 6249 +852 2333 6249 Tel : 電話: 電話: Fax : +852 2356 9798 +852 2356 9798 +852 2356 9798 傳真:...