1.Overview When ordering spare parts, please always specify the appliance model and serial number. Wall bracket Bottom part DEX hood Connecting pipe Non-return valve Flow sensor Thermal sensor set PCB cover CMU PCB Heating element including safety pressure cut-out Control panel support Connecting terminal Safety thermal Inlet pipe...
2.Safety Instructions Warning Installation, initial operation and maintenance of this appliance must only be conducted by an authorised professional, who will then be responsible for adherence to applicable standards and installation regulations. We assume no liability for any damages caused by failure to observe these instructions. Do not use the appliance until it has been correctly installed and unless it is in perfect working order.
3.Technical Specifications DEX 12 ELECTRONIC MPS Model ® Energy efficiency class Power setting 8.0 kW (36.6 A) 10.5 kW (47.7 A) Chosen capacity (Current) @ 220 V 8.8 kW (38 A) 11.5 kW (50 A) @ 230 V 9.6 kW (40 A) 12.5 kW (52.2 A) @ 240 V 1/N/PE 220 V ..
4.Dimensions Dimensions in mm 5.Installation The following regulations must be observed: • Installation must comply with all statutory regulations, as well as those of the local electricity and water supply companies. • The specifications on the rating plate. • Technical specifications. Installation site •...
5.Installation Mounting accessories For installations under difficult conditions, these mounting accessories are available: Mounting kit RDX (Art. no. 34100) The instant water heater can be installed by means of this mounting kit in the below situations. The power supply cable is coming out of the wall at any place from behind the unit, but the wall has unusual surface conditions, making it difficult for installing the water heater.
5.Installation Installing the wall bracket Note If you install this instantaneous water heater in exchange for a conventional instantaneous water heater, there is generally no need to drill holes for the wall bracket, in this case step 2 would not be necessary. Thoroughly rinse the water supply pipes before installation to remove soiling from the pipes.
5.Installation Installing connection pieces Note Fasten the screw nuts with caution, to avoid damage to the valves or the piping system. As shown in the illustration, screw the cold water connection piece with the union nut and the ½” seal onto the cold water connection.
6.Direct Connection Note Fasten the screw nuts with caution, to avoid damage to the valves or the piping system. For direct connection, the two ½” screw-in nipples and the ½” seals must be screwed into the ½” union nuts of the hot-water and cold-water connectors. The two ½”...
7. Electrical Connection Wiring diagram 1.Electronic circuitry 2.Heating element 3.Safety pressure cut-out 4.Terminal strip 5.Safety thermal cut-out Only by a specialist! Please observe: • The installation must comply with current IEC and national local regulations or any particular regulations, specified by the local electricity supply company •...
7. Electrical Connection Electrical connection from below Note If necessary, the connecting terminal can be 180mm displaced to the upper part of the appliance. If 60mm you want to do so, please follow the instructions in the next chapter. Check that the power supply is switched off prior to electrical connection! 1.
7. Electrical Connection Electrical connection from above Check that the power supply is switched off prior to electrical connection! 1. Open the prepared breaking point (S) in the upper part of the appliance by pressing with a blunt implement (e.g. screwdriver). 2.
7. Open the hot water tap. Check the function of the appliance. 8. Explain the user how the instantaneous water heater works and hand over the operating instructions. 9. Fill in the warranty card on P.43 and return to German Pool according to the instructions. P.15...
8. Initial Operation Reinstallation In case the appliance will be commis sioned again under different installation conditions than during its initial ope ration, it may be necessary to adapt the maximum power rating. A temporary short-circuit of the two pins, e.g. with a screwdriver acc.
9. Service menu The service menu offers an overview of system parameters and is used Service menu for diagnostics. Press key and key simultaneously for at least 2 seconds to call up the Press service menu, the display confirms by “FL” and by a flashing point. Using the ≥...
Page 18
9. Service menu “Ch”: Radio channel Menu item order of “Service menu“: (with wireless module only) Information about the current radio channel of the water heater and its remote control. Flow “rS”: Received strength (with wireless module only) Power Information about the current signal quality of the remote control as percentage.
10. Maintenance work Maintenance work must only be conducted by an authorised professional. Cleaning and replacing the filter strainer closed The cold water connection of this instantaneous water heater is equipped with an integrated shut- off valve and a strainer. Soiling of the strainer may reduce the warm water output.
10. Maintenance work Cleaning and replacing the filter strainer if direct connected The cold water connection of this instantaneous water heater is equipped with a strainer. Soiling of the strainer may reduce the warm water output. Clean or replace the strainer as follows: 1.
11.Environment and recycling GERMAN POOL is conscious of the importance of environmental protection. We extend our belief to our packaging materials. You can help the environment by carefully segregating waste. The packaging is essential for protecting the components during transportation. The packaging is made from environmentally- friendly, re-usable corrugated cardboard.
12. How to use As soon as you open the hot water tap, the instantaneous water heater switches on automatically. When the tap is closed, the appliance automatically switches off. Temperature setting You can set the required temperature gradually to a and .
Page 23
12. How to use Temperature limitation Scalding protection on The instantaneous water heater DEX12 is equipped with an optional temperature limiting function. This scalding protection is deactivated in the factory setting. Press ≥ 3 sec Switch on: Select the limit temperature, then press simultaneously for at least 3 sec.
Page 24
Power limit Power limit If the full output of the instantaneous water heater DEX12 does not suffice to heat the tapped quantity of water, this will be indicated by the LCD decimal point (e.g. in winter time, when opening several taps at once).
Contact customer Water stays cold, Customer Service Department at out tripped service digital display lights up GERMAN POOL. Please have the Control system has Switch fuse off and details of the typeplate at hand. switched off on. If “Er“ still flashes...
Quick reference guide Programme button 1 Programme button 2 Arrow keys up and down Set temperature Scalding protection off Power limit +1 °C –1 °C Press ≥ 3 sec Confirmation of deactivation Select preset temperature Scalding protection on Unit provides no output Press ≥...
3.規格 DEX 12電子控制 MPS ® 型號 能源標簽 功率設定 額定功率(電流) @ 220 V 8.0 kW (36.6 A) 10.5 kW (47.7 A) 8.8 kW (38 A) 11.5 kW (50 A) @ 230 V @ 240 V 9.6 kW (40 A) 12.5 kW (52.2 A) 1/N/PE 220 V ..
Page 50
如欲獲取更多有關本產品最新資訊,歡迎瀏覽本公司網站。 For additional product information, please visit our website. w w w . g e r m a n p o o l . c o m . c n...
Page 51
- 產品經非認可之技術人員改裝或加裝任何配件; - serial number is modified, damaged or removed from the product. - 機身編號被擅自塗改、破壞或刪除。 4. German Pool will, in its discretion, repair or replace any 4. 總代理有權選擇維修或更換配件或其損壞部份。 defective part. 5. 產品一經被轉讓,其保用即被視作無效。 5. This warranty will be void if there is any transfer of ownership from the original purchaser.
Page 52
香港九龍土瓜灣馬頭角道116號新寶工商中心二期113號室 Room 113, Newport Centre Phase II, 116 Ma Tau Kok Road, Tokwawan, Kowloon, Hong Kong DEX-12-M-14(1)
Need help?
Do you have a question about the DEX12 and is the answer not in the manual?
Questions and answers