Section 8 - Maintenance And Troubleshooting; Maintenance - DoorKing 9150 Series Installation & Owner's Manual

Hide thumbs Also See for 9150 Series:
Table of Contents

Advertisement

SECTION 8 - MAINTENANCE AND TROUBLESHOOTING

Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or
suspected. High cycle usage may require more frequent service checks.

8.1 Maintenance

When servicing the gate operator, always check any secondary
(external) reversing devices (loops, photocells, etc.) for proper
operation. If external reversing devices cannot be made operable,
do not place this operator in service until the malfunction can be
identified and corrected.
Always check the inherent reversing system when performing any
maintenance. If the inherent reversing system cannot be made
operable, remove this operator from service until the cause of the
malfunction is identified and corrected. Keeping this operator in
service when the inherent reversing system is malfunctioning
creates a hazard for persons which can result in serious injury or
death should they become entrapped in the gate.
When servicing this gate operator, always turn power OFF!!
Operator
Component
Alarm
Batteries
DC Open System
Drive Belt
Chain
Clutch
Fire Dept.
Gate
Grease
Loop(s)
Primary Reverse System
Pulleys
Release
Secondary Reverse Device
Complete System
9150-065-V-12-12
Maintenance
Activate the primary (inherent) reverse system by blocking the
gate with a solid object. When the gate reverses, block the gate
in the opposite direction prior to the limit being reached. The
entrapment alarm should activate. Press the reset button to
silence the alarm.
If operator is equipped with optional DC open system, check the
batteries for any leakage or loose connections. Batteries should
be replaced every two years.
If operator is equipped with optional DC open system, check to
be sure the system opens the gate upon loss of AC power.
Check for alignment, tightness and wear.
Check for sagging. Tighten if necessary.
Check for proper slippage when an obstruction is encountered.
Check emergency vehicle access device for proper operation.
Inspect for damage. Check gate wheels. rollers and guides for
wear and grease if necessary.
Wheels and guide rollers if necessary.
Check vehicular exit and reverse loops for proper operation.
Check that the gate reverses on contact with an object in both
the opening and closing cycles.
Adjust the reversing sensor and/or clutch if necessary.
Check for alignment. Check setscrews.
Check manual release for proper operation.
Check secondary (external) reverse device(s) stop or reverse the
gate when activated.
Complete check of gate and gate operating system.
T
N O
t c h
D O
c l u
o v e
t e .
r e m
p l a
Align clutch plate
holes with screws to
repair solenoid lock.
Every time the 9150 is powered up, the First open
command will automatically run "Multiple gate
cycles" that will locate and remember the gate's
open and close positions (See page 25).
Monthly Interval
3
6
12
✓ ✓
41