SECTION 5 - MAINTENANCE AND TROUBLESHOOTING

Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or
suspected. High cycle usage may require more frequent service checks.
5.1 Maintenance
When servicing the gate operator, always check any secondary (external) reversing devices (loops, photocells, etc.) for proper
operation. If external reversing devices cannot be made operable, do not place this operator in service until the malfunction can
be identified and corrected.
Always check the inherent reversing system when performing any maintenance. If the inherent reversing system cannot be
made operable, remove this operator from service until the cause of the malfunction is identified and corrected. Keeping
this operator in service when the inherent reversing system is malfunctioning creates a hazard for persons which can result
in serious injury or death should they become entrapped in the gate.
When servicing this gate operator, always turn power OFF!!
Operator
Component
Alarm
Chain
Fire Dept.
Gate
Grease
Loop(s)
Primary Reverse System
Release
Secondary Reverse Device
Sprockets
Complete System
30
Maintenance
Activate the primary (inherent) reverse system by blocking the
gate with a solid object. When the gate reverses, block the gate
in the opposite direction prior to the limit being reached. The
entrapment alarm should activate. Press the reset button to
silence the alarm.
Check for sagging. Tighten if necessary.
Check emergency vehicle access device for proper operation.
Inspect for damage. Check gate wheels. rollers and guides for
wear and grease if necessary.
Wheels and guide rollers if necessary.
Check vehicular exit and reverse loops for proper operation.
Check that the gate reverses on contact with an object in both
the opening and closing cycles.
Adjust the reversing sensor if necessary.
Check manual release for proper operation.
Check secondary (external) reverse device(s) stop or reverse the
gate when activated.
Check setscrews for tightness.
Complete check of gate and gate operating system.
Monthly Interval
3
6
12
Draft - Not for Release - 9510-065-D-3-10