5.2 Control Wiring for Single/Primary Operator

Important:
Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while
operating the controls. Outdoor or easily accessible controls should have a security feature to prevent unauthorized use.
Wiring opening device when using
"Manual Mode Operation" for
convenience open operator(s):
The opening device should be wired
to the 2340 circuit board when
using the convenience open
system to "manually open"
the gate(s) during a power
failure. This will allow normal
daily operation as well as AC
power failure operation. This
should ONLY be wired this
way when operating in the
manual mode with
convenience open operators
(See page 39 for more info).
Com
Fire Box
#2-Full Open
#4-Connected device fully opens gate.
#5-Connected device opens gate 14-feet.
Telephone
Entry
Key Switch
Stand-Alone
Keypad
Stand-Alone
Card Reader
Note:
All stand-alone and
telephone entry
devices must use a
separate power
source.
32
3-Wire Radio Receiver
W A
R N
I N
G
M O
V IN
S ER
IO
G
U S
G A
Op
T E
er ate
IN
JU
C A
an
d fre
ga
R Y
N
e of
te
C A
Do
pe
on
ly
O R
U S
no
op
wh
D EA
E
or
op
t all
le
an
en
ga
er ate
ow
d ob
te
TH
Do
ga
ch
ild
str
ar ea
no
te.
re n
uc
tio
is
in
pa
th
t sta
to
pla
ns
sig
wh
nd
y in
.
ht
EX IT
Re
ile
ga
in
ga
ga
ad
te
te
te
LO OP
ow
is
m ov
pa
th
ar ea
ne
r's
ing
or
m an
.
wa
lk
ua
th ro
l an
ug
H
d sa
h
ITC
fet
y ins
KE Y
SW
tru
cti
on
s.
CO
NF
OR
AN
SI /U
M S
TO
CA
L- 32
KI NG
N/
CE
RT
5
CS
IF IE
OR
-0 10
VE
A C2
D
DO
H IC
2. 2
TO
46
02
NO
CL
U LA
. 24
533
AS
R
7
82
S
G AT
1
M OD
E O
PE
2
EL
R AT
3
SE
RI
HP
O R
4
AL
5
VO
LT
S
AM
PS
SW
M AX
GA
PH
AS
TE
E
LO
Do
AD
60
or Ki
Hz
NC
ng
, In
c. ,
NO
In gl
ew
oo
d,
CA
Red Full Open
Green Close
White Com
3-Button Control Station
"Optional" REVERSES GATE for
Closing Direction Photo Sensors
Functions ONLY during gate closing cycle.
SW 2, switch 2: After photo sensor beam
gets obstructed:
OFF Setting - REVERSES GATE.
ON Setting - Stops gate then continues
closing when gate is clear (Same function
as UL 325 terminal #2).
Note: The ON setting is used to help prevent tailgating
but the photo sensor should be wired to the UL 325
terminal #2 when the "stop gate" function is desired,
see page 28 for more information.
Relay -
#2 - Full Open.
#5 - Opens gate 14-feet.
Com
24 volt
250 mamp.
max.
E
RS
RE VE
LO OP
EN
OP
ER
TI M
E
IT Y
RS
RE VE
IT IV
SE NS
2
SW
1
DoorKing ONLY
SW 2
Com
#5 Terminal Note (Single Operator Only):
Any opening device connected to terminal #5
will open the gate to the partial open 14-ft setting.
Secondary entrapment protection devices will also
open the gate to the partial open setting. If the
Inherent Reverse Sensor gets activated during the
close cycle, it will always fully open the gate.
24 Volt - 250 mamp. max.
Relay N.O. - #2 - Full Open.
#5 - Opens gate 14-feet.
Relay Com
24 Volt Com
1
2
Full Open
3
4
Full Open
5
Partial Open
6
7
8
9
10
11
12
13
14
15
16
17
18
4-Wire
Receiver
KEY SWITCH
4602
NC
NO
SW 2,
switch 3
must be
OFF.
SW 2
9150-065-V-12-12

Hide quick links:

Advertisement

Table of Contents
loading