InITIal InsPeCTIon

Be certain to inspect all cartons or crates on each
unit as received at the job site before signing the
freight bill. Verify that all items have been received
and that there are no visible damages; note any
shortages or damages on all copies of the freight
bill. In the event of damage or shortage, remember
that the purchaser is responsible for filing the
necessary claims with the carrier. Concealed
damages not discovered until after removing the
units from the packaging must be reported to the
carrier within 24 hours of receipt.

General desCrIPTIon

These Water-to-Air Heat Pumps provide the best
combination of performance and efficiency
available. Safety devices are built into each unit to
provide the maximum system protection possible
when properly installed and maintained.
The CE Water-to-Air Heat Pumps are Underwriters
Laboratories (UL) and (cUL) listed for safety. The
water-to-Air Heat Pumps are designed to operate
with entering fluid temperature between 25°F to
75°F in the heating mode and between 50°F to
110°F in the cooling mode.
50°F Min. EWT for well water applications with
sufficient water flow to prevent freezing.
Antifreeze solution is required for all closed
loop applications. Cooling Tower/Boiler and
Earth Coupled (Geo Thermal) applications
should have sufficient antifreeze solution to
protect against extreme conditions and
equipment failure. Frozen water coils are not
covered under warranty.
This product should not be used for temporar-
ily heating/cooling during construction. Doing
so may effect the units warranty.

MoVInG and sToraGe

If the equipment is not needed for immediate
installation upon its arrival at the job site, it should
be left in its shipping carton and stored in a clean,
dry area. Units must only be stored or moved in the
normal upright position as indicated by the "UP"
arrows on each carton at all times. If unit stacking is
6 720 220 048
required, stack units as follows: Vertical units less
than 6 tons, no more than two high. Horizontal units
less than 6 tons, no more than three high. "Do not
stack units larger than 6 tons."

safeTY ConsIderaTIons

Installation and servicing of this equipment can be
hazardous due to system pressure and electrical
components. Only trained and qualified personnel
should install, repair, or service the equipment.
Untrained personnel can perform basic functions of
maintenance such as cleaning coils and replacing
filters.
Caution
When working on equipment, always observe
precautions described in the literature, tags, and
labels attached to the unit. Follow all safety codes.
Wear safety glasses and work gloves. Use a
quenching cloth for brazing, and place a fire
extinguisher close to the work area.

loCaTIon

Locate the unit in an indoor area that allows easy
removal of the filter and access panels, and has
enough room for service personnel to perform
maintenance or repair. Provide sufficient room to
make fluid, electrical, and duct connection(s). If the
unit is located in a confined space such as a closet,
provisions must be made for return air to freely enter
the space. On horizontal units, allow adequate room
below the unit for a condensate drain trap and do
not locate the unit above supply piping. These units
are not approved for outdoor installation; therefore,
they must be installed inside the structure being
conditioned. Do not locate in areas that are subject
to freezing.

InsTallaTIon

Caution
Subject to change without prior notice
Initial Inspection
Before performing service or maintenance
operations on the system, turn off main power
to the unit. Electrical shock could cause
personal injury or death.
Remove all shipping blocks under blower
housing. Loosen compressor mounting bolts.
Revised 05-12