Device Requirements
Amps
2.5
5
7.5
10
15
20
25
30
40
NR = Not Recommended.
Storage batteries emit highly explosive hydrogen gas when charged.
Batteries also contain acid, which can cause severe chemical burns.
• Do not allow open flames or cigarettes nearby for several minutes after charging a battery.
• Always wear protective goggles and rubber gloves when charging a battery.
• If battery acid gets on the skin, flush with water.
• If battery acid gets in the eyes, flush with water and immediately call a physician.
• If battery acid is swallowed, drink large quantities of milk and immediately call a physician.

STOPPING THE GENERATOR

To stop this generator:
1. Turn off all connected electrical devices and then unplug them.
2. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator.
3. Turn off the engine switch.
4. If using Propane, turn the propane tank fuel valve to the "off" position.
Allow this generator to cool down before touching areas that become hot during operation.
GEN9000DF 9000 Surge Watt / 7500 Running Watt Portable Dual Fuel LPG Liquid Propane Gas & Gasoline Electric Start Generator Manual
Watts (120V)
Watts (240V)
300
600
600
1200
900
1800
1200
2400
1800
3600
2400
4800
3000
6000
3600
7200
4800
9600
Figure 9 - Maximum Extension Cord Lengths by Power Requirement
Max. Cord Length (ft) by Wire Gauge
#8 wire
#10 wire
#12 wire
NR
1000
600
NR
500
300
NR
350
200
NR
250
150
NR
150
100
175
125
75
150
100
60
125
65
NR
90
NR
NR
#14 wire
#16 wire
375
250
200
125
125
100
100
50
65
NR
50
NR
NR
NR
NR
NR
NR
NR
18